Operating Instructions
VEGAPULS 51K … 54K
4 … 20 mA; HART
®
compact sensor
Question and Answer IconNeed help?

Do you have a question about the Vega VEGAPULS 52K and is the answer not in the manual?

Summary

Safety Information

1 Product Description

1.3 Adjustment

Describes methods for sensor adjustment using PC, module, or handheld.

3 Mounting and Installation

3.4 False Echoes

Identifies causes of false echoes from installations, protrusions, and inflow.

4 Electrical Connection

5 Set-up

6 Diagnostics

Supplement

Safety Manual

Functional safety information according to IEC 61508 / IEC 61511.

1.4 Determination of Safety-Related Characteristics

Defines failure limit values based on SIL class and hardware fault tolerance.

2 Planning

Discusses low demand and high demand/continuous mode operation for safety functions.

4 Reaction During Operation and in Case of Failure

Explains system behavior during operation and failure, including fault signals.

6 Safety-Related Characteristics

Provides failure rate data and safety characteristics for the 1oo1D architecture.

SIL Declaration of Conformity

Declares conformity to IEC 61508/61511 standards, including reliability data.

CE Declaration of Conformity

Declares conformity to EMC and Low Voltage Directives based on EN standards.

Vega VEGAPULS 52K Specifications

General IconGeneral
Accessory TypeAntenna
MaterialStainless Steel
Accuracy±2 mm
Protection classIP68
Housing materialStainless Steel
Communication4-20 mA, HART
Process temperature-40 ... +130 °C (-40 ... +266 °F)