- 17 -
CHRONOS KEY Programmable Thermostat User Manual
5. Once all parameters are set, to exit and to go back to the programming menu, press
the key
for a short time.
To exit and go back to the normal operation (automatic, manual) press the key
for a long time or wait for the time-out expiration (about 30 seconds).
If a timing is active, the display shows the symbol
.
To interrupt a timing, enter again the menu and set the value 00.
Advanced functions menu
With the ADV menu it is possible to modify the following operation parameters:
- operating mode (heating or cooling)
- regulation type (on-off or proportional)
- parameters related to regulation type
- antifreeze temperature
- setting of an external supporting input
- selection of the control probe
- keypad lock by password
- system operation hours.
To enter the menu ADV:
1. From the normal operation display, press the key
for a long time until the
symbol
starts flashing on field (2).
2. Press the key
for a short time until the symbol starts flashing and press
the key
to enter the parameters modification.
3. Now the first parameter of the menu starts flashing:
press the keys
and to modify the parameter and the key to
confirm and move to the next parameter.
To exit the parameters modification press the key
.