Venmar E15 HRV User Manual

Venmar E15 HRV
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
E15 ECM ERV*
E15 ECM HRV*
E15 HRV
E10 HRV
90H-V ECM ERV*
90H-V ECM HRV*
90H-V+
60H-V+
These products earned the ENERGY STAR
®
by
meeting strict energy efficiency guidelines set
by Natural Resources Canada and the US EPA.
They meet ENERGY STAR requirements only
when used in Canada.
21781 rev. 09
READ AND SAVE THESE INSTRUCTIONS
RESIDENTIAL USE ONLY
! !
VB0202
* THE FACTORY SET SPEED FOR THESE UNITS IS NOW FROM 55 CFM
TO 125 CFM (SEE PAGE 12 FOR MORE DETAILS).
USER AND INSTALLER MANUAL
Question and Answer IconNeed help?

Do you have a question about the Venmar E15 HRV and is the answer not in the manual?

Venmar E15 HRV Specifications

General IconGeneral
Airflow @ 0.4 in. w.g.150 CFM
Motor TypePSC
TypeHRV
Airflow Capacity150 CFM
Apparent Sensible Effectiveness60%
Power Supply120V / 60Hz
Weight45 lb

Summary

LIMITATION AND SAFETY SYMBOLS

WARNING SYMBOL DEFINITION

Identifies instructions that might cause serious personal injury or death if not followed.

CAUTION SYMBOL DEFINITION

Identifies instructions that might severely damage the unit or its components if not followed.

1. USING THIS UNIT

1.1 INTEGRATED CONTROL

Explains the unit's booting sequence and the integrated push-button operation.

2. USER SERVICING INSTRUCTIONS

3. USER'S TROUBLESHOOTING

4. WARRANTY

6. INSTALLATION

6.3 INSTALLING THE DUCTWORK AND THE REGISTERS

6.4 INSTALLING THE EXTERIOR HOODS

6.5 CONNECTING THE DUCTS TO THE UNIT

6.6 CONNECTING THE DRAIN

7. CONTROLS

7.2 SPEED AND DEFROST SETTING FOR E15 ECM ERV, E15 ECM HRV, 90H-V ECM ERV AND 90H-V ECM HRV

7.3 ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROLS

8. CONNECTION TO THE FURNACE

9. BALANCING THE UNIT

10. SERVICE PARTS

11. WIRING DIAGRAMS

AVS E15 ECM ERV, AVS E15 ECM HRV, 90H-V ECM ERV & 90H-V ECM HRV UNITS

Wiring diagram and logic diagram for E15 ECM ERV/HRV and 90H-V ECM ERV/HRV units.

AVS E15 HRV AND 90H-V+ UNITS WIRING

AVS E10 HRV AND 60H-V+ UNITS WIRING

12. TROUBLESHOOTING

INTEGRATED CONTROL LED ERRORS

Diagnoses unit issues based on LED signals: GREEN for thermistor, AMBER for damper, RED for motor.

WALL CONTROL TROUBLESHOOTING

Steps to diagnose and resolve issues with optional wall control functionality and display.

UNIT DOES NOT WORK - INTEGRATED CONTROL LED IS OFF

UNIT DOES NOT WORK - INTEGRATED CONTROL LED IS RED AND FLASHING

TROUBLESHOOTING RED/FLASHING LED - UNIT SERIES SPECIFIC

FOR UNITS: E10 HRV, E15 ERV, 90H-V+, 60H-V+

Specific troubleshooting for units E10 HRV, E15 ERV, 90H-V+, 60H-V+.

SUPPLY MOTOR DOES NOT WORK

EXHAUST MOTOR DOES NOT WORK

FOR UNITS: E15 ECM HRV/ERV, 90H-V ECM HRV/ERV

Specific troubleshooting for units E15 ECM HRV/ERV, 90H-V ECM HRV/ERV.

Related product manuals