21784 rev. 09
VB0205
VB0206
RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
! !
USER AND INSTALLER MANUAL
TOP PORTS UNITS
HRV ERV
Constructo 1.0 41502 41506
C12 41552 41556
60H 41602 41606
60H+ 41652 41656
SIDE PORTS UNITS
HRV ERV
Constructo 1.0 41500 41504
C12 41550 41554
60H 41600 41604
60H+ 41650 41654

Other manuals for Venmar 41504

Questions and Answers

  • J
    jennifer06Aug 20, 2025
    What to do if the air from my Venmar Air Conditioner is too cold?
    • N
      nedwardsAug 20, 2025
      If the air from the supply grille of your Venmar Air Conditioner is too cold: * Check whether the exterior hood is blocked. * Try operating the unit on a lower speed ventilation setting, or using intermittent or recirculation mode, if available. * Consider installing a duct heater.
  • C
    csanchezAug 22, 2025
    How to fix dry inside air with Venmar Air Conditioner?
    • S
      Samantha LopezAug 22, 2025
      If the air inside is too dry while using your Venmar Air Conditioner: * Consider using a humidifier temporarily. * If your unit has the option, operate it in recirculation mode.
  • D
    Deborah RobertsAug 25, 2025
    Why is the LED blinking red on my Venmar Air Conditioner?
    • B
      Brandon EscobarAug 25, 2025
      A blinking red LED on the integrated control of your Venmar Air Conditioner indicates a problem. This could be due to: * The door being open while the unit is not unplugged. If this is the case, close the door and press the integrated control push button once to reset the unit. * A problem with the exhaust motor. In this case, contact your installer.
  • J
    Jeremy HayesAug 26, 2025
    How to fix a Venmar 41504 Air Conditioner wall control that does not work?
    • T
      Tanya WyattAug 27, 2025
      If the wall control for your Venmar Air Conditioner isn't working, the issue might be with the wiring or the wall control itself. First, ensure the color-coded wires are correctly connected. Inspect all wires for damage and replace any that are broken. If the wiring seems correct, remove the wall control and test it directly beside the unit with a shorter wire. If it works, replace the original wire in the wall. If it still doesn't work, replace the wall control.
  • C
    cameronmichaelAug 28, 2025
    What to do if my Venmar 41504 Air Conditioner shows error code E1?
    • K
      Kelli CantrellAug 28, 2025
      If the error code E1 appears on your Venmar Air Conditioner's Altitude or Deco-Touch wall control screen, it could be due to wiring issues. Ensure that the color-coded wires are connected correctly. Inspect all wires for any damage and replace if necessary. Also, make sure all wires are securely connected.
  • D
    david59Aug 30, 2025
    Why is the damper actuator not working on my Venmar 41504?
    • N
      nathaniellindseyAug 30, 2025
      If the damper actuator on your Venmar Air Conditioner isn't working, the problem could be a defective actuator, damper mechanism, or circuit board. To troubleshoot, unplug the unit, disconnect the main and auxiliary controls, wait 10 seconds, and plug it back in to see if the damper opens. If not, use a multimeter to check for 24 VAC on J12-1 and J12-2 on the circuit board. If there is 24 VAC, replace the entire damper assembly. Note that a small delay of 7-8 seconds before detecting the 24 VAC signal is normal. If there is no 24 VAC, replace the circuit board.
  • M
    Mark CarlsonSep 2, 2025
    What causes the Dehumidistat to not work on a Venmar Air Conditioner?
    • H
      Hannah ChenSep 2, 2025
      If the Dehumidistat, the 20-minute push button, or the 20/40/60 minute push-button timer on your Venmar Air Conditioner isn't working, or if its indicator light doesn't stay on, it could be due to reversed wires or a defective component. First, ensure that the color-coded wires are connected correctly. If the wiring is correct, jump the OL and OC NO C NC I OC OL Y R G B terminals. If the unit switches to high speed, remove the Dehumidistat or push button and test it right beside the unit using a shorter wire. If it works there, replace the original wire. If it doesn’t, replace the Dehumidistat or the push button.
  • K
    Katherine Pearson DVMSep 4, 2025
    What to do if the defrost cycle isn't working on my Venmar 41504 Air Conditioner?
    • E
      Eric AvilaSep 4, 2025
      If the defrost cycle isn't working on your Venmar Air Conditioner (indicated by a frozen fresh air duct or very cold air), it could be due to ice hindering the damper, a broken damper rod or port damper, or a defective damper actuator or circuit board. To resolve this, start by removing any ice buildup. Inspect the damper rod and port damper for damage, and replace them if necessary. For issues with the damper actuator or circuit board, refer to point 5.
  • M
    Michael CalderonSep 6, 2025
    Why does my Venmar Air Conditioner screen alternate between normal display and E3?
    • H
      Heather EscobarSep 6, 2025
      If the Altitude or Deco-Touch wall control screen of your Venmar Air Conditioner alternates between the normal display and E3, the wall control itself may be defective. In this case, the suggested solution is to replace the Altitude or Deco-Touch wall control.
  • L
    Lauren ShepherdSep 8, 2025
    How to fix no outdoor temperature display on my Venmar Air Conditioner?
    • S
      Sheryl HughesSep 8, 2025
      If there is no outdoor temperature displayed on your Venmar Air Conditioner's Altitude wall control screen, the unit thermistor may be defective (the integrated control LED of the unit must flash GREEN). If this is the case, replace the unit thermistor.

Summary

Using This Unit

Integrated Control Operation

Describes the unit's booting sequence and integrated control operation.

User Servicing Instructions

Installation Procedures

Unit Preparation for Installation

Steps to prepare the unit before installation.

Unit Location Selection

Guidance on choosing an appropriate location for the unit.

Attic Installation Considerations

Specific considerations for installing the unit in an attic.

Ductwork and Register Installation

General guidelines for installing ductwork and registers.

Exterior Hood Installation

Instructions for installing exterior hoods, including warnings.

Unit Controls

Optional Wall Control Electrical Connection

Instructions for connecting optional wall controls to the unit.

Furnace Connection

Unit Balancing Procedure

Wiring Diagrams