8.1 EVERY THREE MONTHS (cont’d)
6. Reinstall the components:
Heat recovery core
Filter
Door (The door is secured when you hear a click.)
7. Check the exterior
air intake hood
:
Make sure there are no leaves, twigs, ice or snow that could be drawn into
the vent.
Clean if necessary.
8. Set the wall control to its previous position (FAE115M, uFAE115M and
vFAE115M only).
CAUTION
Even a partial blocking of this air vent could cause the unit to
malfunction.
TYPE OF PROBLEM TRY THIS...
1 Nothing works. See if the transformer is plugged in.
(models FAE115M, uFAE115M See if the transformer is receiving
and vFAE115M only) power from the house circuit breaker.
2 Condensation on windows. Adjust the humidity control knob as
(Air too humid.) per instructions (see Section 7)
(FAE115M, uFAE115M and vFAE115M
models only).
Leave curtains half-open to allow air
circulation.
Store all firewood in a close room
with a dehumidifier or in a well
ventilated room, or store the wood
outside.
Keep the temperature in your house
above 18°C (64°F).
3 Air too dry. Adjust your humidity control over
the click (FAE115M, uFAE115M and
vFAE115M models only).
Temporarily use a humidifier.
9.0 Troubleshooting
If you think your unit is malfunctioning, check some of the following.