20503 REV. 10
VB0253
THESE PRODUCTS EARNED THE ENERGY
STAR
®
BY MEETING STRICT ENERGY EFFICIENCY
GUIDELINES SET BY NATURAL R ESOURCES CANADA
AND THE US EPA. THEY MEET ENERGY STAR
REQUIREMENTS ONLY WHEN USED IN CANADA.
USER AND INSTALLER MANUAL
RESIDENTIAL USE ONLY
VB0254
HRV CONSTRUCTO 1.5ES
46110
HRV CONSTRUCTO 2.0ES
47110
HRV SOLO 1.5ES
46720
HRV SOLO 2.0ES
47720
HRV NOVOFIT 1.5ES
46121
HRV NOVOFIT 2.0ES
47121
100H
1601706
200H
1601708
NOVO+ 100H
1601717
NOVO+ 200H
1601719
READ AND SAVE THESE INSTRUCTIONS

Other manuals for Venmar HRV CONSTRUCTO 2.0ES

Questions and Answers

  • H
    Heather HuntAug 14, 2025
    What to do if there is condensation on windows when using Venmar Fan?
    • T
      thomasalisonAug 14, 2025
      If you notice condensation on the windows due to high humidity when using the Venmar Fan: * Operate the unit at maximum speed during activities that generate excess humidity, such as family gatherings or extra cooking. * Leave curtains half-open to improve air circulation. * Store firewood in a closed room with a dehumidifier, a well-ventilated room, or outdoors. * Maintain a house temperature above 18°C (64°F).
  • B
    briangilmoreAug 18, 2025
    Why is the air too cold at the air supply grille of my Venmar Fan?
    • A
      Andrew WhiteAug 18, 2025
      If the air feels too cold at the air supply grille of your Venmar Fan, verify that the outdoor hoods are not blocked. Also, operate the unit at low speed. If the problem persists, have the system's balancing and the unit's defrost system checked. Consider installing a duct heater.
  • S
    Sarah CoxAug 21, 2025
    How to fix a noisy Venmar Fan?
    • J
      Jennifer RobersonAug 21, 2025
      If your Venmar Fan unit is noisy, start by cleaning it. If the noise continues after cleaning, contact your installer.
  • B
    breannaevansAug 25, 2025
    What to do if air is too dry when using Venmar Fan?
    • S
      Scott GarciaAug 25, 2025
      If the air is too dry when using the Venmar Fan: * Operate the unit at low speed. * Temporarily switch to the intermittent mode (if available). * Use a humidifier temporarily.
  • R
    Ronald JacksonAug 27, 2025
    Why is there condensation on my windows with my Venmar HRV CONSTRUCTO 2.0ES?
    • W
      Walter WatsonAug 28, 2025
      If you notice condensation on your windows and the air feels too humid, try the following: * Adjust the humidity control knob according to the instructions. * Operate the unit at maximum speed (MAX.) during activities that generate excess humidity, such as family gatherings or extensive cooking. * Leave curtains half-open to allow for better air circulation. * Store firewood in a closed room with a dehumidifier, a well-ventilated room, or outside. * Maintain a house temperature above 18°C (64°F).
  • S
    Sara HullAug 31, 2025
    What to do if my Venmar HRV CONSTRUCTO 2.0ES isn't working?
    • J
      jamie41Aug 31, 2025
      If your unit isn't working, check to see if it is plugged in and receiving power from the house circuit breaker or fuse.
  • R
    russelljosephSep 3, 2025
    Why is my Venmar Ventilation Hood so noisy?
    • S
      Steven JohnsonSep 3, 2025
      If your unit is noisy, try cleaning it. If the problem persists after cleaning, contact your installer.
  • R
    rodriguezpeterSep 7, 2025
    Why is the air from my Venmar HRV CONSTRUCTO 2.0ES's supply grille too cold?
    • K
      Kevin HarrisSep 7, 2025
      If the air from the supply grille is too cold, make sure the outside hoods are not blocked. You can also try operating the unit at low speed (MIN.). Furthermore, have the system’s balancing and defrost system checked, and consider installing a duct heater.
  • M
    Michael AndersonSep 10, 2025
    How to fix dry air with my Venmar HRV CONSTRUCTO 2.0ES?
    • I
      imaySep 12, 2025
      If the air is too dry: * Avoid adjusting your humidity control below -20° C (30%). * Operate the unit at low speed (MIN.). * Temporarily switch to the intermittent mode. * Use a humidifier temporarily.

Summary

LIMITATION

USING THIS UNIT

Your ventilation system

Explains the unit's function for providing fresh air and exhausting stale air, including humidity control.

Integrated Control

Details the unit's booting sequence and integrated control features like LED indicators for speed.

USER SERVICING INSTRUCTIONS

Quarterly Maintenance

Steps for cleaning filters, condensation tray, and exterior air intake hood.

Annual Maintenance

Procedure for cleaning the recovery core and blower assembly.

USERS TROUBLESHOOTING

WARRANTY

RULES TO FOLLOW

Instructions for contacting the contractor or service center for warranty claims.

REPLACEMENT PARTS AND REPAIR

Emphasis on using genuine manufacturer parts for repairs and maintenance for optimal performance.

BILL OF PURCHASE

Requirement to provide a copy of the original bill of purchase for warranty service.

MISCELLANEOUS COSTS

Clarification that labor costs for part removal/installation are not covered by the warranty.

CONDITIONS AND LIMITATIONS

Defines residential use and limitations for commercial/industrial applications.

AIR DISTRIBUTION

INSTALLATION

PREPARING THE UNIT

Instructions for inspecting the unit for damage and removing the shipping bracket before installation.

LOCATING THE UNIT

Guidelines for choosing an appropriate location, considering temperature, access, and proximity to utilities.

INSTALLING THE DUCTWORK AND THE REGISTERS

FULLY DUCTED SYSTEM

Details on installing stale air exhaust and fresh air distribution ductwork for a fully ducted system.

EXHAUST DUCTED SYSTEM - SUPPLY SIDE

Instructions for connecting to the furnace supply duct for exhaust and fresh air distribution.

EXHAUST DUCTED SYSTEM - RETURN SIDE

Instructions for connecting to the furnace return duct for exhaust and fresh air distribution.

SIMPLIFIED INSTALLATION - RETURN;SUPPLY

SIMPLIFIED INSTALLATION - RETURN;RETURN

INSTALLING THE EXTERIOR HOODS

CONNECTING THE DUCTS TO THE UNIT

CONNECTING THE DRAIN

CONTROLS

SETTING EXTENDED DEFROST

Procedure to set the unit to extended defrost for cold climate operation.

ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROL

Details electrical connections for various optional wall control units.

ALTITUDE OR PLATINUM

Wiring diagram for Altitude or Platinum wall controls.

DECO-TOUCH

Wiring diagram for Deco-Touch wall controls.

LITE-TOUCH CONSTRUCTO, SIMPLE-TOUCH CONSTRUCTO OR LITE-TOUCH BRONZE

Wiring diagrams for specific Lite-Touch and Simple-Touch controls.

CONSTRUCTO OR BRONZE

Wiring diagrams for Constructo or Bronze wall controls.

OPTIONAL AUXILIARY CONTROLS

Wiring diagrams for optional auxiliary controls like Dehumidistat and timers.

CONNECTION TO THE FURNACE

BALANCING THE UNIT

SERVICE PARTS

WIRING DIAGRAM

TROUBLESHOOTING