EasyManua.ls Logo

Ventis HE275CF - Specifications

Ventis HE275CF
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 9
Installation and Operation Manual - HE275CF
ENGLISH
2.2 Specifications
Maximum log length
10
20 in (508 mm) east-west
Flue outlet diameter 6 in (150 mm)
Recommended connector pipe diameter 6 in (150 mm)
Type of chimney ULC-S629, UL 103 HT (2100 °F)
Baffle material C-Cast
Approved for mobile home installation
11
No
Type of door Simple, glass with steel frame
Type of glass Ceramic glass
Particulate emission standard
12
EPA / CSA B415.1-10
USA standard (Safety) UL 127
Canada standard (Safety) ULC S610
10
North-south: ends of the logs visible, East-west: sides of the logs visible.
11
Mobile homes (Canada) or manufactured homes (USA): The US Department of Housing and Urban Development describes “manufactured homes”
better known as “mobile homes” as follows; buildings built on xed wheels and those transported on temporary wheels/axles and set on a permanent
foundation. In Canada, a mobile home is a dwelling for which the manufacture and assembly of each component is completed or substantially
completed prior to being moved to a site for installation on a foundation and connection to service facilities and which conforms to the CAN/CSA-
Z240 MH standard.
12
Tested and certied in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17.

Table of Contents