Technical specications
External sensor: NTC 10 kOhm at 25° C
Sensor values:
15°C
18°C
20°C
22°C
14,8 kOhm
13,1 kOhm
12,1 kOhm
11,2 kOhm
Display: LCD
Power consumption: <2W
Set-point range: Room: 5°C to 35°C
Floor: 20°C to 35/45°C
Accuracy: ±1°C
Buttons: Touch pad
Switch current rating: <13A (resistive load)
Mains voltage: 85-240V~
Dimensions: 86 x 86 x 13 mm (WxHxD)
Fixing screw width: 60mm
Housing: ABS + PC Flame Retardent
Operating rating: 0~30°C, 5~95% RH (non-con-
densing)