9
Basic functionality
READING THE FLOOR TEMPERATURE (only in program mode 3
and 5)
With the thermostat turned on.
Press “M” once, the “ FT ” will be ashed, and the display will
show the oor temperature.
In program mode 2 (oor sensor) the display always shows the current
oor temperature.
In program mode 1 and 4 (room sensor) the display always shows the
current room temperature.
FROST PROTECTION MODE
To enable frost protection mode.
With thermostat turned o.
Press “M” for 3 seconds.
Select 01 (00 = disabled)
When enabled and thermostat has been turned o, the heating will be
activated if the room/oor temperature is lower than 5°C; the heating
will be stopped if the room/oor temperature is higher than 7°C.
When frost protection mode has been enabled the display will show
”.
EN