EasyManuals Logo

Verint nextiva s1800e series User Manual

Verint nextiva s1800e series
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
No Authentication:No authentication is used.
MD5 Authentication:The Message Digest Version 5 (MD5) hash function is used to
determine that the message is from a valid source.
SHA Authentication:The Secure Hash Algorithm (SHA) has function is used to
determine that the message is from a valid source.
11. In the User Authentication Password box, type a password for the user.
12. In the User Privacy Protocol list, select the privacy protocol to encrypt the contents of the
data. You can select from the following:
No Encryption:No encryption is used.
DES Encryption:The Data Encryption Standard (DES) algorithm is used to encrypt the
data.
AES Encryption:The Advanced Encryption Standard (AES) algorithm is used to encrypt
the data.
13. In the User Privacy Password box, type a password for the privacy protocol.
14. Click Apply.
Viewing MIB Information
You can download the device Management Information Base (MIB) and use a SNMP application to
view the information. The MIB is a collection of manageable entities of the device network element.
The S1800e series device sends a coldStart trap when it is initialized and sends the following Verint-
Specific SNMP traps:
Video Signal Loss edVinMediaStateAnalogNotif trap. This trap is generated if an analog video
input of an S1800e series device is disconnected or reconnected with the following information:
Input number (1 to 16 for S1816e and S1816e-SP, 1 to 8 for S1808e)
New state (0: not connected, 1: connected)
Dry Input State Change edDigitalinPinStateNotif trap. This trap is generated if the status of a
digital alarm dry contact input of the S1800e device has changed with the following information:
Input number (1 to 16 for S1816e and S1816e-SP, 1 to 8 for S1808e)
New state (0: not connected, 1: connected)
edVinCamtampOofAlarmStateNotif trap. This trap is generated if the Out Of Focus status of an
input has changed with the following information:
[0x00]= Not Out Of Focus
[0x01]= Out Of Focus
Perform the following steps:
1. Start the Web Interface.
2. From the tree, select Configuration >SNMP.
Setting the SNMP Properties
91
www.verint.com/video_solutions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Verint nextiva s1800e series and is the answer not in the manual?

Verint nextiva s1800e series Specifications

General IconGeneral
BrandVerint
Modelnextiva s1800e series
CategoryMedia Converter
LanguageEnglish

Related product manuals