Installation
Installation place
Select a location that is suitable for work and near to an air source and 100-240V AC supply.
Hose
Use an air hose (ODφ6 mm x IDφ4 mm) of sufficient withstanding pressure performance.
Air
Remove all impurities with a mist separator (0.3μm). Remove all moisture with an air dryer.
(Dew-point temperature: -15˚C or less)
Supply air at a temperature of 0~40˚C.
*Be sure to supply clean air only because oil-mixed air may cause the discharge stop.
Grounding
Connect to the AC power source with a ground.
CAUTIONS IN INSTALLATION
REMEMBER
Use only the included power supply adapter. Use of other adapters may results
in fire, electric shock and static electricity removal failure.
REMEMBER
Use an air hose of sufficient withstanding pressure performance.
Air hoses of insufficient withstanding pressure may rupture and leak air.
REMEMBER
Install the G2-E in the following environment.
Adverse environments cause product deterioration and breakdown.
Humidity: 35~65%RH (No dew condensation or freezing) Temperature: 5~45˚C
PROHIBITED
Do not use the G2-E in the following environments. Adverse environments
cause product deterioration and breakdown, as well as personal accidents.
Where explosion-proofing is required; where in flammable atmospheres, high
temperature and high humidity, or sharp temperature fluctuations; where
dewing occurs; where possibly wet by water, oil or solvent.
PROHIBITED
Do not pull excessively the hose and cable. Abusive handling can damage the
gun and internally disconnect the power cable and air hose.