SPECIFICATIONS MODELSS240
FLOOR MODEL GRAVITY FEED
Air Cooled Units
Air cooled units require a minimum of 6 (200 mm) of clearance on all sides of the
freezer. Failure to allow for adequate clearance can reduce the refrigeration capacity of the
Electrical Hook-Up Installation for 220V-240V, 60 Hertz, 1 Phase
Check the data label in the rear panel for electrical specications. The power supply must
be connected through the circuit breaker. This equipment is supplied with a 3-wire cord
.The cord provided for is 16 amp, therefore the wall outlet must over 16 Amp.
Equipment Parameters
Freezing Cylinder
Two,2 x 1.6 Liters
Mix Hopper
Two,2 x 12.5Liters
DIMENSIONS:
NET: 554x654x1340mm (WxDxH)
Packing: 650x800x1665mm (WxDxH)
WEIGHT
Net: 190kg Packing: 210kg
ELECTRICAL
Voltage AC: 1 Phase ,220-240V 60 Hz
Total Run Amps: 16 Amps
Power:2500W
rive Motor: One, 2.0HP
Refrigeration System
Main Compressor: One,5039BTU/hr R404a
Pre-cooling Compressor: 400 BTU/hr R134a
(BTU may vary depending on compressor
used.)
AIR COOLING
Air-cooled required minimum 152mm air
clearance around the freezer.
CAUTION:
THIS EQUIPMENT MUST BE PROPERLY GROUNDED! FAILURE TO DO
SO CAN RESULT IN SEVERE PERSONAL INJURY FROM ELECTRICAL SHOCK!