EasyManua.ls Logo

Victron energy MultiPlus Compact 12/800/35-16 User Manual

Victron energy MultiPlus Compact 12/800/35-16
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Manual
Handleiding
Manuel
Anleitung
Manual
MultiPlus Compact
12 | 800 | 35-16 230V 24 | 800 | 16-16 230V
12 | 1200 | 50-16 230V 24 | 1200 | 25-16 230V
12 | 1600 | 70-16 230V 24 | 1600 | 40-16 230V

Questions and Answers:

Victron energy MultiPlus Compact 12/800/35-16 Specifications

General IconGeneral
ModelMultiPlus Compact 12/800/35-16
Input Voltage12 V
Input Voltage Range9.5 - 17 V
Output Power (Continuous)800 VA
Output Power (Surge)1600 VA
Output Voltage230 V
Output Frequency50 Hz
Efficiency90%
Charger Output Current35 A
Charge Current35 A
Battery Voltage12 V
ProtectionOverload, Short circuit, Overtemperature
AC Input Voltage Range187-265V

Summary

1. SAFETY INSTRUCTIONS

General Safety Advice

General safety advice before using the equipment.

Installation Safety Instructions

Instructions for safe and proper installation of the product.

Transport and Storage Guidelines

Guidelines for safely storing and transporting the product.

2. PRODUCT DESCRIPTION

General Product Overview

Overview of the MultiPlus Compact's multiple functions and features.

Battery Charger Functionality

Details about the adaptive 4-stage battery charging system.

Solar Energy Storage Systems

How the MultiPlus works in solar energy storage systems.

3. PRODUCT OPERATION

On/Off/Charger Only Switch

Explanation of the product's main operational switch settings.

Remote Control Methods

Methods for controlling the MultiPlus remotely.

Equalisation and Forced Absorption

Procedures for activating specific battery charging modes.

LED Status Indicators

Interpretation of the product's LED status indicators.

4. PRODUCT INSTALLATION

Installation Location Requirements

Recommended placement and environmental conditions for installation.

Battery Cable Connections

Guidance on connecting battery cables correctly.

AC Cabling Connections

Instructions for connecting AC input and output cables.

Optional Connection Options

Details on various optional connection possibilities.

5. PRODUCT CONFIGURATION

Standard Factory Settings

Default factory settings for out-of-the-box operation.

Explanation of Configuration Settings

Detailed explanations of various configurable settings.

Computer Configuration Setup

Methods for configuring the product using computer software.

VE.Net Panel Configuration

How to configure settings using a VE.Net panel.

DIP Switch Configuration

Using DIP switches to adjust product settings.

7. ERROR INDICATIONS AND TROUBLESHOOTING

General Error Indications

Common problems and their solutions based on error indications.

Special LED Indications

Specific LED indications beyond general error codes.

VE.Bus LED Error Codes

VE.Bus system specific LED codes for OK and error states.

8. TECHNICAL DATA

APPENDIX A: Connection Overview

Appendix B: Installation Information

APPENDIX C: Parallel Connection

APPENDIX D: Three-Phase Connection

APPENDIX E: Charge Curve

APPENDIX F: Temperature Compensation

APPENDIX G: Dimensions

Related product manuals