MultiPlus 500VA – 1200VA
MultiPlus 12 | 500 | 20 230V
MultiPlus 24 | 500 | 10 230V
MultiPlus 48 | 500 | 6 230V
MultiPlus 12 | 800 | 35 230V
MultiPlus 24 | 800 | 16 230V
MultiPlus 48 | 800 | 9 230V
MultiPlus 12 | 1200 | 50 230V
MultiPlus 24 | 1200 | 25 230V
MultiPlus 48 | 1200 | 13 230V
Question and Answer IconNeed help?

Do you have a question about the Victron energy MultiPlus 12 and is the answer not in the manual?

Victron energy MultiPlus 12 Specifications

General IconGeneral
ModelMultiPlus 12
Input Voltage230 VAC
Output Voltage230 VAC
Efficiencyup to 93%
Transfer time20 ms
CoolingConvection
Battery voltage range9.5 - 17 V

Summary

Safety Instructions

General Safety, Shock Hazard, and Lifting

General precautions, electric shock hazard, and lifting advice.

Installation Safety Guidance

Read installation instructions before installing the equipment.

Product Description

Multifunctional Features and Operation

Multifunctional aspects, AC power, parallel/3-phase, PowerControl and PowerAssist features.

Operation Guide

Main On/Off/Charger-Only Switch

Functionality of the primary on/off and charger-only switch.

LED Status Indicator Meanings

Interpretation of LED indications for inverter and charger status.

Installation Procedures

Installer Qualification and Safety

Emphasizes that installation must be performed by a qualified electrician.

Battery Cable Connection Procedure

Instructions for correctly connecting battery cables based on capacity and cross-section.

AC Cabling and Grounding Instructions

Procedures for connecting AC input and output cables safely.

Programmable Relay and Parallel Setup

How to connect multiple units in parallel for increased power.

Parallel Connection Requirements and Best Practices

Essential requirements for successful parallel connection of multiple units.

Configuration Settings

Configuration by Qualified Personnel Only

Settings must only be changed by a qualified engineer.

Troubleshooting Guide

General Troubleshooting Approach

General procedure for detecting and resolving common faults.

Inverter Operation and Alarm Issues

Solutions for inverter failing to operate or showing alarm indications.

Charger and Battery Charging Faults

Solutions for charger not functioning or battery not charging properly.

Appendix C: Parallel Connection

Appendix D: Three-Phase Connection

Appendix E: Charge Algorithm

Detailed Four-Stage Charging Process Explanation

Detailed explanation of the Bulk, Battery Safe, Absorption, Float, and Storage charging stages.