Quattro
(with firmware xxxx400 or higher)
12 | 5000 | 220 – 100|100 – 230V
24 | 5000 | 120 – 100|100 – 230V
48 | 5000 | 70 – 100|100 – 230V
24 | 8000 | 200 – 100|100 – 230V
48 | 8000 | 110 – 100|100 – 230V
48 | 10000 | 140 – 100|100 – 230V
48 | 15000 | 200 – 100|100 – 230V

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Victron energy Quattro 24/8000/200 and is the answer not in the manual?

Victron energy Quattro 24/8000/200 Specifications

General IconGeneral
ModelQuattro 24/8000/200
Rated Power8000 VA
Output Voltage230 VAC
Efficiency94%
Transfer time20 ms
Battery voltage24 VDC
Peak power16000 VA
Protection categoryIP22
Output Frequency50 Hz
Input voltage range19.0 - 33.0 V

Summary

1. SAFETY INSTRUCTIONS

General Safety and Usage

General safety guidelines, electrical shock warning, and product usage advice.

Installation, Transport, and Storage

Guidance on safe installation, transport, and storage procedures.

2. DESCRIPTION OF FEATURES

Core Functions and Advanced Features

Overview of Quattro's key functions like AC inputs/outputs, parallel operation, PowerControl/Assist.

Specialized Features

Details on programmable relays, I/O ports, frequency shift, and battery monitor.

Solar Energy and Emergency Power

2.2 Battery Charger Operation

Details adaptive 4-stage charging, BatterySafe, Storage mode, and temperature compensation.

Absorption Time and Voltage Sense

Explains variable absorption time and voltage sensing for accurate charging.

2.3 Self-Consumption Systems

Discusses grid code compliance and system integration for solar storage.

3. OPERATION

Operating Switch and Remote Control

Explains the main switch function and remote control options.

3.3 Special Charging Modes

Explains and details how to activate equalisation and forced absorption modes.

3.4 LED Indicators and Meanings

Inverter Operation LED States

Explains LED indicators for inverter mode.

Charger Operation LED States

Explains LED indicators for charger mode.

Special and Combined LED Indications

Battery Charger Specific LED States

Special Indications for Input Current

4. INSTALLATION GUIDELINES

Location and Battery Cable Connection

Guidelines for installation location and connecting battery cables.

4.3 AC Cable Connections

AC Input and Output Connections

Details for connecting AC inputs (AC-in-1, AC-in-2) and outputs (AC-out-1, AC-out-2).

4.4 Connection Options

Battery, Sensor, and Remote Connections

Details on starter battery, voltage sense, temp sensor, and remote control connections.

Auxiliary Output and Multi-Unit Connectivity

Details on AC-out-2, parallel, and three-phase connection of Quattro units.

5. CONFIGURATION

Standard Settings and Parameter Explanations

Overview of default settings and explanation of inverter/input parameters.

Multi-Unit and Feature Configuration

System Configuration Settings

Settings for multi-unit operation, AES, Search Mode, and Ground Relay.

Battery Charging Configuration

Settings for charging characteristics, battery type, equalisation, absorption time, storage, and bulk protection.

Advanced Configuration Settings

AC Input Current Limit and UPS Features

Setting AC limits for PowerControl/Assist and configuring the UPS feature.

Generator and System Support Features

Details on Dynamic Current Limiter, WeakAC, relays, I/O ports, frequency shift, and battery monitor.

5.3 Computer Configuration Software

5.4 VE.Net Panel Configuration

5.5 DIP Switch Configuration

DIP Switch Setup Procedure

Step-by-step guide for configuring settings via DIP switches.

Step 1: Current Limit Settings

Setting AC input and battery charge current limits using DIP switches.

DIP Switch Configuration Examples (Step 1)

Step 2: Other DIP Switch Settings

Charging Voltages and Absorption Time

Configuring charging voltages, absorption time, and adaptive charging via DIP switches.

Other Feature Settings via DIP Switches

Configuring dynamic current limiter, UPS, converter voltage, and frequency via DIP switches.

DIP Switch Configuration Examples (Step 2)

6. MAINTENANCE

7. ERROR INDICATIONS

General Error Troubleshooting

Table of common problems, their causes, and solutions.

Special and VE.Bus LED Indications

Special LED Indications

Details specific LED combinations and special states.

VE.Bus OK and Error Codes

Explains VE.Bus OK codes and how to interpret error codes using LED patterns.

8. TECHNICAL SPECIFICATIONS

Model and Inverter Specifications

Summary of Quattro models and technical details of the inverter function.

Charger, General, and Safety Specifications

Details on charger specs, general characteristics, and compliance standards.

APPENDIX B: Block Diagram

APPENDIX C: Parallel Connection

APPENDIX D: Three-Phase Connection

APPENDIX E: Charge Characteristic

APPENDIX F: Temperature Compensation

APPENDIX G: Quattro Dimensions

Dimensions of Wall Mounting Plate

Dimensions of Specific 24V/48V 5kVA Models

Dimensions of 48V 5kVA-S Models

Dimensions of Quattro 15kVA

Dimensions of 15kVA Wall Mounting Plate