Scrolling text LCD Description
YIELD TOTAL The cumulative PV yield since the last history reset.
LAST ERROR
The last 4 errors since the last history reset. Only available
if there actually were any error(s):
• E0 - Total error 0 (most recent)
• E1 - Total error 2 (shown when available)
• E2 - Total error 3 (shown when available)
• E3 - Total error 4 (shown when available)
PANEL VOLTAGE
MAXIMUM
The maximum PV voltage since the last history reset.
BATTERY VOLTAGE
MAXIMUM
The maximum battery voltage since the last history reset.
YIELD
The daily PV yield, available for each day for the past 30
days.
BATTERY VOLTAGE
MAXIMUM
The daily maximum battery voltage, available for each day
for the past 30 days.
BATTERY VOLTAGE
MINIMUM
The daily minimum battery voltage, available for each day
for the past 30 days.
LAST ERROR
The last 4 daily errors. Only available if there actually were
any error(s):
• E0 - Total error 0 (most recent)
• E1 - Total error 2 (shown when available)
• E2 - Total error 3 (shown when available)
• E3 - Total error 3 (shown when available)
TIME BULK
Daily time spent in bulk charge stage or in ESS, in minutes,
available for each day for the past 30 days. *
TIME ABSORPTION
Daily time spent in absorption charger stage, in minutes,
available for each day for the past 30 days. *
* When the charger is not active (night time) the bulk, absorption and float icons will be shown as in the table above. When
the charger is active only one icon will be shown: the icon corresponding to the actual charge state.
SmartSolar Control display manual