6
Inspection and maintenance
The inspection and maintenance of a heating system
is prescribed by the Energy Saving Ordinance [EnEV -
Germany] and the DIN 4755, DVGW-TRGI 2008 and
DIN 1988-8 standards.
Regular maintenance ensures trouble-free, energy effi-
cient, environmentally responsible and safe heating.
Your heating system must be serviced by an author-
ised contractor at least every 2 years. For this, it is
best to arrange an inspection and maintenance con-
tract with your local heating contractor.
DHW cylinders
Standards DIN 1988-8 and EN 806 specify that main-
tenance and cleaning should be carried out no later
than 2 years after commissioning and as required
thereafter.
Only a qualified contractor should clean the inside of
the DHW cylinder and the DHW connections.
If any water treatment equipment (e.g. a sluice or
injection system) is installed in the cold water supply of
the DHW cylinder, ensure this is refilled in good time.
For this, observe the manufacturer's instructions.
We recommend that the correct function of the sacrifi-
cial anode be checked annually by your qualified con-
tractor.
The function of the sacrificial anode can be checked
without interrupting the system operation. The contrac-
tor will check the earth current with an anode tester.
Safety valve (DHW cylinder)
The function of the safety valve must be checked
every six months by the user or a contractor through
venting (see valve manufacturer's instructions). The
valve seat may become contaminated.
Water may drip from the safety valve during a heat-up
process. The outlet is open to the atmosphere and
must not be closed off.
Potable water filter (if installed)
To maintain high hygienic standards, proceed as fol-
lows:
Replace filter element on non-back flushing filters
every six months (visual inspection every
two months).
On back flushing filters, back flush every
two months.
Damaged cables / lines
If there is damage to the connecting cables or lines of
the appliance or externally installed accessories, these
must be replaced with special cables or lines. Only use
Viessmann cables / lines as replacement. For this,
notify your qualified contractor.
Maintenance
Maintenance
5686 598 GB

Other manuals for Viessmann VITOCELL 100-W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann VITOCELL 100-W and is the answer not in the manual?

Viessmann VITOCELL 100-W Specifications

General IconGeneral
BrandViessmann
ModelVITOCELL 100-W
CategoryBoiler
LanguageEnglish

Related product manuals