Coding in
the as
delivered
condition
Address:
value
Function mode Coding
change
Address:
value
Possible change
ing mode, the inter nal
circulation pu mp is per-
manently OFF
to
F6:24
mode, the intern al circu-
lation pump will be
started1to24timesper
day for 10 minu tes
respectively
F6:25 In "DHW only" operating
mode, the intern al circu-
lation pump is pe rma-
nently ON
F7:10
*
6
In "Standby mode",
the interna l ci rculation
pump will be started 10
times per day for 10
minutes respe ctively
F7:0 In "Standby mode", the
internal circulation pump
is permanently OFF
F7:1
to
F7:24
In "Standby mode", the
internal circulation pump
willbestarted1to24
times per day for 10 min-
utes respectively
F7:25
*
6
In "Standby mode", the
internal circulation pump
is permanently ON
Resetting the coding to the delivered condition
1. Press L and G simult aneously
for approx. 2 se conds.
2. Press e.
Confirm "Basic setting? Yes"
with d.
With a or b, you can select
"Basic settin g? Yes " o r "Basic set-
ting? No".
Code 2 (cont.)
63
Coding
5692 537 GB
*6
Only for constant temperature control u nits.