Viessmann Vitodens 300 - Page 81

Viessmann Vitodens 300
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Displayed
fault c ode
Con-
st.
Weat -
her-
com-
p.
System
character-
istics
Cause Remedy
C2 X X Control
mode
Communica-
tion fault -
solar control
unit
Check connecti ons
andcodingaddress
54
C5 X X Control
mode,
max. pump
speed
Communica-
tion fault -
variable speed
internal pump
Check codin g
address 30 set-
tings; check the DIP
switch settings in
thepumpwiring
chamber:
Switch 1: OFF (as
delivered condition)
Switch 2: OFF (as
delivered condition)
C6 X Control
mode,
max. pump
speed
Communica-
tion fault -
variable speed
heating circuit
pump, heating
circuit M2
Check codin g
address E5 set-
tings; check the DIP
switch settings in
thepumpwiring
chamber:
Switch 1: OFF
Switch 2: ON
C7 X X Control
mode,
max. pump
speed
Communica-
tion fault -
variable speed
heating circuit
pump, heating
circuit A1
Check codin g
address E5 set-
tings; check the DIP
switch settings in
thepumpwiring
chamber:
Switch 1: ON
Switch 2: OFF
Cd X X Control
mode
Communica-
tion fault Vito-
com 100 (KM
BUS)
Check connecti ons
and Vitocom 100
CE X X Control
mode
Communica-
tion fault - ext.
extension
Check connecti ons
andcodingaddress
2E settings
Checking and acknowledging faults (cont.)
81
Troubleshooting
5692 537 GB