Vitopend 222 for o pen f lue operation
&
Wall mounted boiler for natural gas and LPG to DVGW Code of
Practice G260 [Germany] and EN 437
&
With modulating atmospheric burner
&
Components integrated into the equipment:
DHW primary cylinder
"Aqua-Bloc" hydraulic unit with multi-connect system
Diaphragm expansion vessel
Single stage heating circuit pump
Diverter valve with stepper motor
&
Fully plumbed and wi red
&
Packed separately:
Vitotronic 100 for constant temperature operation
or
Vitotronic 200 for weather-compensated operation
Natural gas/LPG version
&
The Vitopend is factory-fitted for natural gas.
&
A kit for conversion to LPG is supplied to order.
Vitopend 222 for balanced flue operation
&
Wall mounted boiler for natural gas and LPG to DVGW Code of
Practice G260 [Germany] and EN 437
&
With modulating pressure-jet burner
&
Two-stage fan with automatic flue gas adaptation
&
Components integrated into the equipment:
DHW primary cylinder
"Aqua-Bloc" hydraulic unit with multi-connect system
Diaphragm expansion vessel
Single stage heating circuit pump
Diverter valve with stepper motor
&
Fully plumbed and wi red
&
Packed separately:
Vitotronic 100 for constant temperature operation
or
Vitotronic 200 for weather-compensated operation
Natural gas/LPG version
&
The Vitopend is factory-fitted for natural gas.
&
A kit for conversion to LPG is supplied to order.
Design information
Installation for balanced flue operation
The Vitopend is a boiler type B
22
,B
32
,C
12
,C
12x
,C
32
,C
32x
,C
42x
,
C
52
,C
62
,C
82
or C
82x
to TRGI '86/96.
&
The Vitopend can be installed for balanced fl ue operation inde-
pendent of the size and ventilation of the boiler room.
&
It may, for exa mple, be installed in rooms with personnel traffic
or in accommodation rooms, in ancill ary rooms without ventila-
tion, in cupboards and recesses without maintaining minimum
clearances to combustible c omponents as well as in attic rooms
(pitched attics and ancillary rooms) where the balanced flue
pipe can be directly routed through the roof.
&
The installation location must be safe from the risk of frost.
&
The maximum ambient temperatu re of the system should not
exceed 45 °C.
&
Provide a drain i n the boiler room for the blow-off line of the
safety valve and, if required, for the condensate trap of the
balanced flue system.
&
Electrical interlocks for extractors (extractor hoods, etc.) are not
required with balanced flue operation.
Installation for open flue operation
As equipment of type B
11BS
is being installed, the boiler room is
subject to the following requirements to TRGI '86/96:
&
Avoid air contamination through halogenated hydrocarbons (e.
g. as in sprays, paints, solvents and cleaning agents)
&
Avoid very dusty conditions
&
Avoid high levels of humidity
&
Protect against frost and ensure good ventil ation
&
Provide a drain i n the boiler room for the blow-off line of the
safety valve.
&
The maximum ambient temperatu re of the system should not
exceed 45 °C.
&
Secure the Vitopend near the chimney stack/duct.
&
In rooms where air contamination from halogenated hydrocar-
bons is to be expected, operate the boiler only in bala nced f lue
mode.
If these instructions are not observed, any consequenti al losses
directly related to any of these causes are excluded from our war-
ranty.
Installation location
Permissible:
&
Boiler installation on the same floor
&
Living space with interconnected room ventilation
&
Adjacent rooms with interconnec ted room ventilation (larders,
basement, utili ty rooms, etc.)
&
Adjacent rooms with apertures to the outside (ventilation air/
extract air 150 cm
2
or each with 2 × 75 cm
2
at the top and bottom
of the same w all)
&
Attic rooms, but only with adequate minimum chimney height (to
DIN 18160 4 m above inlet).
Not permissible:
&
Stair wells and common hallways; exception: detached and two
family homes of low height (top edge of the floor i n the top
storey < 7 m above ground level)
&
Bathrooms and toilets without outside windows with duct venti-
lation
&
Rooms in which explosive or flammable materials are stored
&
Rooms which are ventilated mechanically or via individual duct
systems to DIN 18117-1.
5822 335-1 GB
28 VIESMANN VITOPEND 222
Delivered condition