Control panel VMN3 (cont.)
■
DHW CIRCULATION PROGRAM (only available when DHW circulation is active):
A Period number according to schedule (max. 5)
B Start time for DHW circulation
C End time for DHW circulation operation
– Numbers 1 to 8 > Setting of 8 daily programs per
day program. There are 5 adjustable periods in
which the DHW circulation pump runs.
The process for setting daily programs is described
in Daily planning.
– Weekly: Assignment of one setting per day of the
week for the set daily programs.
■
Pasteurisation (only available in systems with
a DHW cylinder):
– Temperature: Cylinder temperature during
pasteurisation
– Day of the week: Day for pasteurisation in the
automatic program
– Time: Time required for pasteurisation in the
automatic program
– Runtime: Time required for pasteurisation
(calculated from the moment the pasteurisation
temperature is reached)
– Automatic mode:
Yes – start pasteurisation automatically at the
specied time (time, day of the week)
No – automatic pasteurisation is disabled.
Pasteurisation is only carried out at the
request of the system operator.
– DHW circulation: Pasteurisation can be activated
for the entire system or only for DHW
– Start now: Starts pasteurisation manually
(regardless of set day and time).
■
Date/time:
– Sets the current system time
(year, month, day of month, time).
– Automatic time change:
Yes – automatically changes the system time
between summer and wintertime
No – automatic time change is disabled.
■
Language:
– Menu language selection.
■
User interface:
– MIN. Brightness: Setting the brightness of the
display in standby mode.
– MAX. Brightness: Setting the brightness of the
display during operation.
– Tone:
Yes – tone when operating the rotary power
switch
No – no tone when operating the rotary power
switch
– Sensitivity of the rotary switch:
1 – high / 4 – low.
■
System:
– Type: VMx3 (ID).
– MSK program: Program version for boiler control.
– PW program: Version of the control panel
program.
– Maximum rated output: Set boiler output.
– Reset: Start the boiler.
– Default factory setting: Restore.
Heating circuit settings
If more than one heating circuit is installed, select the
corresponding heating circuit from the list. If only one
heating circuit is installed, a parameter list is displayed
for it.
■
Heating circuit program (only available with source
and cylinder modules). The daily and weekly
program settings are made in the same way as
for the central heating program.
■
System:
– Stop:
Yes – no heating circuit operation
No – normal heating circuit operation.
– Reset – restart the heating circuit control unit
– Version of the heating circuit control unit
Settings