89
Get-Function table
A.  Basic function
Get Function  Length ID Command 
Type
Command  Response Range  Comments
(ASCII) Code (ASCII)  Code (Hex) (Three ASCII bytes) 
Get-Bright-
ness 
8 g b 62 000 ~ 100 
Get-Volume  8 g f 66 000 ~ 100 
Get-Mute 8 g g 67 000: Off
001: On (muted)
Get-Input 
select
8 g j 6A  000~ 
100~
1.  1st digit for signal 
detection: 0 
means “no signal”; 
1 means “signal 
detected”
2.  2nd &3rd digit: 
See Set-function 
table
Get-Power 
status: ON/ 
STBY
8 g l 6C 001: ON
000: STBY
Get-Remote 
control 
S g n 6E 000: Disable
001: Enable
002: Pass through
Get RCU mode 
status
Get-Power 
lock
8 g o 6F 000: Unlock
001: Lock
Get-Button 
lock
8 g p 70 000: Unlock
001: Lock
Get-Menu 
lock
8 g l 6C 000: Unlock
001: Lock
Get-ACK 8 g z 7A 000 This command is 
used to test the com-
munication link
Get-Thermal 8 g 0 30 000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
Get-Opera-
tion time
*3.1.0
8 g 1 31 000 1.   Accumulated 
hours in 8-digit in-
teger (00,000,001~ 
99,999,999)
2.  Could be reset 
when FW update 
and Factory initia-
tion
3. Reply in 4 strings
Get-Device 
name
8 g 4 34 000 Reply in 6 strings 
(max. 12 characters) 
*3.1.0
Get-MAC ad-
dress
8 g 5 35 000 (for the model with 
LAN)
Reply in 6 
strings.*3.1.0