Push buttons
This lets you manage push-button conguration.
• ID setting (*)
Starts the "call button remapping" procedure.
• Module order
Starts the procedure of assigning the order of the button modules.
• Grouping: Rocker, Single, Double buttons (*)
Lets you choose the type of grouping of the outdoor station.
Addressing (*)
Used to start the outdoor and indoor station addressing procedures.
• Indoor Stations
Starts the indoor station address assignment procedure.
• Outdoor Stations
Starts the (non secondary) outdoor station address assignment procedure.
• Manual addressing
The ID of the outdoor station and type of system can be changed for the segment it is connected to.
Timing
This lets you choose the times for:
• Lock
Lock command duration
• Talk
Maximum talk duration
• Answer
(*)
Time available for answering a call after the ringtone cycles have ended.
• Self-start
(*)
You can select the maximum duration of the self-start time.
If the entrance panel has been congured for a horizontal system or as a master for a vertical system, an additional parameter
is present to allow enabling/disabling of the cyclic self-start function.
• F1
(*)
It is possible to select the control activation time and destination from among the local panel modules.
• F2
(*)
It is possible to select the control activation time and destination from among the local panel modules.
• Keypad Relay
(*)
It is possible to select the actuator activation time and the relative source, i.e. the relay ID.
The source may therefore have a value from 1 to 16 for vertical systems and 1 to 6000 for expanded systems. Zero disables
the function, while to set the local panel lock control as the source press the key button on art. 41019 when entering the control.
The “Activation delay” parameter can only be congured in SaveProg
34