59
7559 Tab 4.3
Cannot be configured from the Indoor Station but visible if configured using SaveProg. The following table, taken from
the SaveProg help, it is in the SELF-START/ENTRANCE PANEL line.
Display of specific entrance panel self-start
In the case of an incoming call for which, according to the previous table, the indoor station does not show the video
signal, the display will be as follows:
The video signal of the outdoor station can be shown with key ; at the same time, any other Indoor Stations which
are showing it for the same call are switched off even if they continue to ring and/or can still answer.
TYPE
7559
T1 T2 T3 T4
FREE
SELF-START/ENTRANCE
PANEL
AUXILIARY
F1
SPECIFIC F1
F2
SPECIFIC F2
SPECIFIC LOCK
GEN. LOCK
CALL FROM VIDEO OUTDOOR STATION
FLAG 1 IN SAVEPROG
(MONITOR ON)
RESULT
Direct
ACTIVE Switches on
NOT ACTIVE Does not switch on
Indirect (belongs to a group with only one secondary unit)
ACTIVE Switches on
NOT ACTIVE Does not switch on
Indirect (belongs to a group with at least two secondary units)
ACTIVE Does not switch on
NOT ACTIVE Does not switch on
Call from video outdoor station