EasyManua.ls Logo

Vimar ELVOX 7559 - Page 59

Vimar ELVOX 7559
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
7559 Tab 4.3
Cannot be configured from the Indoor Station but visible if configured using SaveProg. The following table, taken from
the SaveProg help, it is in the SELF-START/ENTRANCE PANEL line.
Display of specific entrance panel self-start
In the case of an incoming call for which, according to the previous table, the indoor station does not show the video
signal, the display will be as follows:
The video signal of the outdoor station can be shown with key ; at the same time, any other Indoor Stations which
are showing it for the same call are switched off even if they continue to ring and/or can still answer.
TYPE
7559
T1 T2 T3 T4
FREE
SELF-START/ENTRANCE
PANEL
AUXILIARY
F1
SPECIFIC F1
F2
SPECIFIC F2
SPECIFIC LOCK
GEN. LOCK
CALL FROM VIDEO OUTDOOR STATION
FLAG 1 IN SAVEPROG
(MONITOR ON)
RESULT
Direct
ACTIVE Switches on
NOT ACTIVE Does not switch on
Indirect (belongs to a group with only one secondary unit)
ACTIVE Switches on
NOT ACTIVE Does not switch on
Indirect (belongs to a group with at least two secondary units)
ACTIVE Does not switch on
NOT ACTIVE Does not switch on
Call from video outdoor station

Other manuals for Vimar ELVOX 7559

Related product manuals