3.3.2.3 Starting the automatic indoor station ID assignment procedure
Requires that the number of users has been congured in advance (valid if the outdoor station is master).
1. Press push button 6 for at least 4 seconds.
2. Operation completed conrmed by a beep and a “conrm the operation” signal.
3. Press the rst push button from which to start associating the IDs (from top to bottom) within 30 seconds, otherwise the
device exits the conguration status. The device exits the conguration status also after pressing the push button.
4. The timeout for the automatic indoor station ID assignment procedure is after 30 minutes or can be exited by pressing push
button 6 for 4 s (the “exit status” beep is emitted), after having returned to conguration mode pressing push button 7.
If the outdoor station is not master, a visual and acoustic “operation not permitted” signal is given.
If not previously disabled
1
7
4s
6
beep
6s
7
6
within 30 s
beep
1
3
2
4
1
3
4
2
beep
2 3
4 4
Timeout 30 minutes
1
1