8
7511131
5) INTENDED AND IMPROPER USES OF THE ST AIRLIFT
5.1) Intended uses
The Mod. V64/74 stairlift is a system for transporting one person SEATED ON A WHEELCHAIR OR ON
A SPECIAL SEAT (optional) with STRAIGHT rail at CONSTANT gradient which can be installed on stairs
having the following characteristics:
- Ambient: Indoor and outdoor
- Steps: Parallel
- Gradient: Minimum 0° - Maximum 50°
User characteristics: Self-sufcient, physically and mentally suitable, familiar with the equipment’s
operation and the use and maintenance instructions.
WARNING: If the person using the system is not self-sufcient, the stairlift must be operated
by another person acting as attendant. While the lift is in motion, sit still and do not move or rock.
5.2) Improper uses
- Transporting objects on the platform
- Overloading the stairlift (e.g., disabled person with electric wheelchair having total weight in excess
of the maximum permitted load. See section 4, Technical Specications).
- Use of the stairlift by unauthorised persons (e.g. children, people who do not meet the requirements
specied in point 5.1)
Improper uses Problems
Use on stairs having gradient
greater than 50°: Overheating of motor
User standing on platform: Risk of falling
Operation by unsuitable operator: Risk of falling
Transporting more than one person: Risk of falling and of overheating of motor
WARNING: DO NOT MAKE MODIFICATIONS INTENDED FOR ANY USE, DO NOT INSERT EXTRA-
NEOUS OBJECTS OR LIQUIDS IN HOLES OR CRACKS, DO NOT SPRAY LIQUIDS ONTO THE STAIRLIFT
6.1) Preliminary checks
Checks to be made before the lift is put into service.
Skill level: OS - Specialist operator appointed by the manufacturer.
ORGANO CONTROLLATO RISULTATO DEL CONTROLLO
ITEM CHECKED RESULT OF CHECK
Controls: Correct operation in response to controls.
Correct timing of the start-up controls.
Efciency of emergency stop.
Safety devices: Check that the safety device is tripped, stopping the lift.
- Sensor edges
- Electric limit switches
- Over-run safety device
- Anti-crushing platform base
Power supply: Mains voltage and frequency as specied in point 6.2.
Earth connection: Check that the lift system’s earth line is connected to the earth
line of the mains system.
6) PREPARATION FOR COMMISSIONING
7512131