37
© 2009 Directed Electronics. All rights reserved.
5 UNLOCK OUTPUT—
1
, 2 PULSES:
This programs the unlock output to one or two pulses. When in two pulse
setting, the BLUE unlock wire supplies two negative pulses instead of
a single pulse. This makes it possible to directly interface with double
pulse vehicles without any extra parts.
6 LOCK OUTPUT—
1
, 2 PULSES:
This programs the lock output to one or two pulses in two pulse setting.
The GREEN lock wire supplies two negative pulses instead of a single
pulse. This makes it possible to directly interface with double pulse
vehicles without any extra parts.
7 FACTORY ALARM DISARM—
WITH UNLOCK
, BEFORE UNLOCK,
REMOTE START ONLY:
In the default setting the factory alarm disarm output will disarm the fac-
tory alarm system any time the buttons controlling Unlock is pressed. The
“Before Unlock” output disarms the factory alarm before the unlock output
activates and before remote start is activated. The “Remote Start Only”
output disarms the factory alarm only before the remote start is activated.
8 FACTORY ALARM DISARM PULSES—
1
, 2 PULSES:
Selectable for a single or double-pulse for the vehicle’s factory alarm dis-
arm input requirements.
9 COMFORT CLOSURE—
OFF (1)
: The system can be programmed to
close the windows when the system is locked. If programmed ON, the
lock output provides a 20 second pulse when the system is locked. The
output will be cancelled if the unlock button is pressed. In the Off setting
the system will not do this function. (2) Comfort closure 1 - Activates the 20
second timer after the door lock pulse. (3) Comfort Closure 2 - Activates
the 20 second timer with the door lock pulse.