Sensor Replacement
Models: D4+, E4+, F4+
Section 1 Safety Information
Please read this entire instruction sheet before operating this equipment. Pay attention to all danger, warning, and caution
statements in this instruction sheet. Failure to do so could result in serious personal injury or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this equipment in any manner
other than that specified in the instruction sheet.
1.1 Safety Precautions
DANGER
Failure to follow these instructions will result in serious injury or death.
Shock Hazard - Stored Energy
Disconnect power to system before performing any maintenance or repair.
There may be more than one source of power. Only connect to a GFCI.
Protective ground
DO NOT touch with wet hands.
Pressurized Device - Impalement Hazard
NEVER perform any physical inspection, repair or maintenance on UV chamber unless UV chamber has been isolated and depressurized.
NEVER service UV lamps, quartz sleeves or associated hardware until depressurization of UV chamber has been confirmed.
DO NOT store any combustible or flammable material close to the system.
WARNING
Failure to follow these instructions could result in serious injury or death.
UV Light Hazard
ALWAYS use UV protective gear, including gloves and UV safety glasses.
NEVER look directly at illuminated UV lamp, even when using protective gear.
NEVER illuminate UV lamp outside of the UV chamber.
If accidental exposure occurs, immediately cool affected area and consult physician.
Contamination Hazard
If UV lamp breaks, avoid inhalation, ingestion, or exposure to eyes and skin. Wear appropriate clothing and personal protective equipment.
NEVER use a vacuum cleaner to clean up broken UV lamps as this will scatter the mercury. Obey local regulations and guidelines for the removal
and disposal of mercury waste.
WARNING: This product can expose you to chemicals including Phthalates, which are known to the State of California to cause cancer and birth
defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Instruction Sheet
UV
603051_RevP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viqua D4+ and is the answer not in the manual?

Viqua D4+ Specifications

General IconGeneral
Flow Rate12 GPM (45 LPM)
Power Consumption60W
Inlet/Outlet Size3/4" MNPT
Chamber Material304 Stainless Steel
ApplicationPoint-of-Entry
Maximum Operating Pressure125 psi (8.6 bar)
UV Dose30 mJ/cm²
Lamp Life9000 hours
Voltage100-240V
Operating Temperature36°F - 104°F (2°C - 40°C)
Power SupplyElectronic Ballast
Amperage0.5A @ 120V