EasyManua.ls Logo

Viqua D4 - User Manual

Viqua D4
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (US and Canada only)
t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069
e-mail: info@viqua.com
www.viqua.com
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (US et Canada seulement)
t. (+31) 73 747 0144 (Europe seulement) • f. (+1) 519.763.5069
Courriel : info@viqua.com
www.viqua.com
425 Clair Rd. W, Guelph, Ontario, Canadá N1L 1R1
t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (solo EE. UU. y Canadá)
t. (+31) 73 747 0144 (solo Europa) • f. (+1) 519.763.5069
correo electrónico: info@viqua.com
www.viqua.com
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (US and Canada only)
t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069
e-mail: info@viqua.com
www.viqua.com
Model:
D4, E4, F4
+ Models:
D4+, E4+, F4+
Validated Models:
D4-V, E4-V, F4-V
D4-V+, E4-V+, F4-V+
Owners Manual
Powered by
603037_RevO

Questions and Answers

  • D
    Desiree BrownJul 27, 2025
    Why Viqua Water System has no power?
    • J
      Justin RobinsonJul 27, 2025
      The Viqua Water System might not have power due to several reasons: the GFCI or breaker tripped (reset it), the transient voltage surge suppressor (TVSS) is damaged (replace it), or the controller is damaged (replace the controller and use a TVSS).
  • G
    gsandersJul 31, 2025
    What to do if the lamp timer on my Viqua Water System doesn't read anything?
    • K
      kevin85Jul 31, 2025
      If the lamp timer on your Viqua Water System isn't displaying anything, check the following: ensure the unit is plugged into a working AC power outlet, replace the fuse or reset the breaker if there's no power at the outlet, replace the power cord if it's damaged, or replace the controller and use a surge protector (TVSS) if a power surge damaged the electrical assembly.
  • D
    Doris GloverAug 6, 2025
    Why does the GFCI or breaker repeatedly trip on my Viqua Water System?
    • D
      David ZimmermanAug 6, 2025
      If the GFCI or breaker repeatedly trips on your Viqua Water System, it could be due to a wet connection between the lamp and lamp plug (clean and dry them, and check for leaks or condensation) or a short-circuit in the electrical assembly (replace the controller).
  • A
    Andre McbrideAug 10, 2025
    What to do if Viqua Water System is operating but water tests show bacterial contamination?
    • A
      Anita CurryAug 10, 2025
      If your Viqua Water System is running but water tests still show bacterial contamination, consider these possibilities: ensure the UV system is the last piece of treatment equipment, as equipment downstream might be a breeding ground for pathogens; ensure all distribution lines have been disinfected with chlorine; remove any pipe dead-ends and flush with chlorine.
  • R
    robinbranchAug 15, 2025
    How to fix a leak from the UV chamber area of Viqua Water System?
    • L
      Lisa ParkerAug 16, 2025
      If you notice a leak from the UV chamber area of your Viqua Water System, the cause might be condensation of moist air on the cold chamber (control humidity or relocate the unit), a damaged, deteriorated, or incorrectly installed O-ring (inspect and replace if needed), or the lamp/sleeve assembly not properly installed (tighten the assembly hand-tight).
  • S
    singhwilliamAug 21, 2025
    How to fix a leak at the inlet or outlet of my Viqua Water System?
    • W
      Wendy LopezAug 21, 2025
      If there's a leak at the inlet or outlet of your Viqua Water System, the threaded pipe fittings may be leaking. Clean the threads, reseal with Teflon tape, and retighten them.

Summary

Safety Information

Potential Hazards

Lists various safety symbols and their meanings related to system hazards.

Safety Precautions

Details essential safety measures for operating and handling the UV system.

Water Chemistry Requirements

Specifies recommended water quality parameters for optimal UV system performance.

General Information

Dimensions and Layout

Illustrates system dimensions, component layouts, and clearances for maintenance.

Installation

Installing the UV System

Step-by-step guide for mounting the system and making plumbing connections.

Disinfection Procedure

Procedure for chemically disinfecting the plumbing system after UV unit installation.

Operation

Control Panel Overview

Explains the control panel features, buttons, display, and indicator lights for system status.

Maintenance

Replacing the UV Lamp

Detailed procedure for safely replacing the UV lamp annually.

Cleaning and Replacing Quartz Sleeve

Guide for cleaning or replacing the quartz sleeve to maintain UV light transmission.

Troubleshooting

Low UV Alarms and Sensor Issues

Addresses low UV alarms and troubleshooting steps for models equipped with sensors.

Specifications

Manufacturers Warranty

How to Make a Warranty Claim

Outlines the process for making a warranty claim, including required documentation.

Specific Warranty Coverage Details

Details warranty periods for various system components like the chamber, electrical parts, and lamps.

General Warranty Conditions and Limitations

Lists exclusions and limitations that apply to all VIQUA product warranties.

Viqua D4 Specifications

General IconGeneral
Chamber Material304 Stainless Steel
Inlet/Outlet Port Size3/4" MNPT
Maximum Operating Pressure125 psi (8.6 bar)
Flow Rate12 GPM
Lamp Life9000 hours
Lamp TypeUV
TypeUV Water Disinfection System
Maximum Water Hardness< 7 grains (120 mg/L)
Power SupplyElectronic Ballast
Warranty3 years