TroubleshootingInformación general
Section 6 Troubleshooting
Symptom Possible Cause Possible Solution
No power
GFCI and/or breaker tripped Reset GFCI and/or breaker
Transient voltage surge suppressor (TVSS) damaged Replace TVSS
Controller damaged Replace controller and use a TVSS
GFCI or breaker repeatedly
trips
Connection between lamp and lamp plug is wet
Clean and dry lamp pins and lamp plug, check unit for leaks
or condensation
Short-circuit in the electrical assembly Replace controller
Leak at inlet or outlet Threaded pipe fittings are leaking Clean threads, reseal with Teflon tape and retighten
Leak detected from area of UV
chamber
Condensation of moist air on cold chamber (slow
accumulation)
Control humidity or relocate unit.
O-ring damaged, deteriorated or incorrectly installed Inspect and replace if deteriorated.
Lamp/sleeve assembly not properly installed (too tight or not
tight enough)
Tighten assembly hand-tight.
Leak detected at sensor (if so
equipped)
UV sensor O-rings are damaged, deteriorated, or incorrectly
installed
Inspect and replace O-rings if deteriorated
Alarm Refer to Section 4.1. Refer to Section 4.1.
System is operating but water
tests reveal bacterial
contamination
Equipment downstream of UV system is acting as a breeding
ground for pathogens
Ensure UV is the last piece of treatment equipment
Pathogens are residing in the distribution lines post-UV
Ensure all distribution lines have been disinfected with
chlorine. Refer to Section 3.2.
Recontamination from pipe dead-ends
Remove any pipe dead-ends and flush with chlorine. Refer to
Section 3.2.
Lamp timer does not read
anything
Unit is unplugged. Plug unit into AC power outlet
No power at AC power outlet Replace fuse or reset breaker
Power cord is damaged Replace power cord
Power surge caused damage to electrical assembly Replace controller and use a surge protector (TVSS)
Para saber qué modelo tiene usted, mire la etiqueta en el lateral del controlador tal y como se describe a continuación:
Elemento Descripción N.º pieza Sistemas UV
15
Kit de válvula solenoide (opcional)
(incluye caja de empalmes)
650717-001 D4 (3/4”)
650717-002 E4, F4, F4+ (1")
16 Válvula CoolTouch (opcional)
650537 D4, D4+, D4-V, D4-V+ (3/4”)
650538 E4, E4+, E4-V, E4-V+, F4+(1") F4-V (1"), F4-V+ (1")
17 Junta tórica 002026 Usado en todos los modelos
Figura 2 Componentes del controlador del modelo D/E/F-
Parámetros de funcionamiento D4/D4+/D4-V/D4-V+ E4/E4+/E4-V/E4-V+ F4/F4+/F4-V/F4-V+
Mantenimiento sin herramientas
Tapa de seguridad y enchufe de lámpara especial Sí Sí Sí
Indicador de funcionamiento de la lámpara Sí Sí Sí
Indicador de funcionamiento del controlador
Indicador de funcionamiento del sensor D4+ E4+ F4+
Sensor D4+ E4+ F4+
Ficha de referencia
Pantalla del temporizador de la lámpara Sí Sí Sí
Botón de restablecimiento del temporizador de la lámpara Sí Sí Sí
Botón de silenciamiento Sí Sí Sí
Válvula de solenoide Opcional Opcional Opcional
Relé de control externo Opcional Opcional Opcional
120-240 VAC, 50-60Hz, 1A
NÚMERO DE SERIE #: 000001
PIEZA #: "B"
FECHA DE FABRICACIÓN:
UV STERILIZER
98HA
"A"
"SYSTEM DESCRIPTION"
425 Clair Road West, Guelph,
ON N1L 1R1 Canadá
Tel. 519 763 1032
Fax 1 800 265 7246
www.viqua.com
100
1,2A
Máx. UV D4 120 v 3/4NPT
MODELO: D4
LÁMPARA DE REPUESTO: 602805
LÁMPARA DE REPUESTO: 602805

Related product manuals