EasyManua.ls Logo

Viqua VH200 - User Manual

Viqua VH200
24 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (US and Canada only)
t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069
e-mail: info@viqua.com
www.viqua.com
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (US et Canada seulement)
t. (+31) 73 747 0144 (Europe seulement) • f. (+1) 519.763.5069
Courriel : info@viqua.com
www.viqua.com
425 Clair Rd. W, Guelph, Ontario, Canadá N1L 1R1
t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (solo EE. UU. y Canadá)
t. (+31) 73 747 0144 (solo Europa) • f. (+1) 519.763.5069
correo electrónico: info@viqua.com
www.viqua.com
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (US and Canada only)
t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069
e-mail: info@viqua.com
www.viqua.com
Models:
VH200, VH410, VP600, VP950
VH410M, VP600M, VP950M
Owners Manual
Powered by
520110_RevL

Other manuals for Viqua VH200

Questions and Answers

  • A
    Abigail LeAug 18, 2025
    What to do if I see a lamp failure alarm on a new lamp in my Viqua VH200 Water Filtration Systems?
    • D
      David AguilarAug 18, 2025
      If the lamp failure alarm is on for a new lamp in your Viqua Water Filtration System, disconnect the lamp from the connector and reconnect, ensuring a tight fit is accomplished. Moisture build-up in the connector may also keep the lamp and connector from making a solid connection. Eliminate any chance of moisture getting to the connector and/or lamp pins.
  • M
    Madison AndrewsAug 20, 2025
    What to do if the lamp failure alarm is on with a new lamp in my Viqua Water Filtration Systems?
    • A
      alanthompsonAug 20, 2025
      If the lamp failure alarm is on even with a new lamp in your Viqua Water Filtration System, consider these possibilities: * Loose connection: Disconnect the lamp from the connector and reconnect it, ensuring a tight fit. * Moisture build-up: Eliminate any chance of moisture reaching the connector or lamp pins, as this can prevent a solid connection.
  • K
    Kendra StricklandAug 22, 2025
    Why is there a pressure drop in my Viqua Water Filtration Systems?
    • T
      Terry WaltersAug 22, 2025
      A pressure drop in your Viqua Water Filtration System can occur if the sediment pre-filter is clogged. Replace the filter cartridge with an appropriate 5-micron cartridge. It can also be caused by contamination in water lines after the UV system. In this case, shock the effluent water stream with chlorine (bleach) before the water leaves the UV system. The disinfection system must have a bacteria-free distribution system to work effectively. Another cause is a possible breakthrough of sediment through the pre-filter. Have your source water tested for turbidity and consider stepped filtration, using a 20-micron filter followed by a 5-micron filter before the UV system.
  • J
    Jessica HarrisAug 25, 2025
    Why are there high bacteria counts in my Viqua VH200?
    • R
      ryanellisAug 26, 2025
      High bacteria counts in your Viqua Water Filtration System can occur if the quartz sleeve is stained or dirty. Clean the sleeve with a scale cleaner and eliminate the source of the staining problem, for example, soften hard water. Also, changes in feed water quality can cause high bacteria counts. Have your source water tested to ensure that the water quality is still within allowable limits for this system.
  • S
    sandra20Aug 28, 2025
    What to do if my Viqua VH200 Water Filtration Systems is shutting down intermittently?
    • A
      Alfred AndersonAug 28, 2025
      If your Viqua Water Filtration System is shutting down intermittently, ensure the system has been installed on its own circuit, as other equipment may be drawing power away from the UV, such as a pump or fridge. Also, the UV system should not be installed on a circuit which is incorporated into a light switch.
  • K
    Kristen WoodwardAug 30, 2025
    How to fix a Viqua VH200 Water Filtration Systems unit leaking water?
    • T
      Travis DyerAug 30, 2025
      If your Viqua Water Filtration System unit is leaking water, check the O-ring seal on the retaining ring and/or UV sensor. Ensure the O-ring is in place, check for cuts or abrasions, clean the O-ring, moisten it with water/lubricant, and re-install. Replace it if necessary. Condensation on the chamber caused by excessive humidity and cold water can also cause leaks. Check the location of the disinfection system and control humidity. Finally, check the thread connections of the inlet/outlet port connections, reseal with Teflon® tape, and re-tighten.
  • R
    Ronnie LoweSep 2, 2025
    What to do if my Viqua Water Filtration System is leaking water?
    • K
      kennethburchSep 2, 2025
      If your Viqua Water Filtration System is leaking water, there are several potential causes: * A problem with the O-ring seal: Ensure the O-ring is correctly placed, inspect it for damage (cuts or abrasions), clean it, and moisten it with water or a lubricant before reinstalling. Replace the O-ring if necessary (410867). * Condensation on the chamber: This can be due to excessive humidity and cold water. Check the location of your disinfection system and control the humidity. * Inadequate inlet/outlet port connections: Inspect the thread connections, reseal them with Teflon® tape, and re-tighten.
  • J
    Joshua OwensSep 4, 2025
    How to fix pressure drop in my Viqua VH200 Water Filtration Systems?
    • L
      Laurie VelasquezSep 4, 2025
      A pressure drop in your Viqua Water Filtration System can be caused by a clogged sediment pre-filter. Replace the filter cartridge with an appropriate 5-micron cartridge. Also, check your source water supply, as fluctuations may occur in source pressure.
  • M
    Michael WattsSep 7, 2025
    Why does my Viqua Water Filtration System have high bacteria counts?
    • C
      Carla ButlerSep 7, 2025
      High bacteria counts in your Viqua Water Filtration System can stem from several issues: * A stained or dirty quartz sleeve: Clean the sleeve with a scale cleaner and address the source of the staining (e.g., soften hard water). * Changes in feed water quality: Have your source water tested to ensure it remains within allowable limits for the system. * Contamination in water lines after the UV system: Shock the effluent water stream with chlorine (bleach) before it exits the UV system. A bacteria-free distribution system is crucial for effective disinfection. * Sediment breakthrough through the pre-filter: Test your source water for turbidity. You might need stepped filtration, using a 20-micron filter followed by a 5-micron filter before the UV system, to capture all sediment.
  • M
    mchapmanSep 9, 2025
    Why my Viqua VH200 keeps shutting down intermittently?
    • E
      ericlewisSep 9, 2025
      If your Viqua Water Filtration System is shutting down intermittently, it could be due to an interrupted controller. Ensure the system is installed on its own circuit, as other equipment may be drawing power. The UV system should not be on a circuit connected to a light switch.

Summary

Safety Information

Potential Hazards

Describes various symbols and their meanings related to system operation and safety.

Safety Precautions

Outlines critical safety measures to prevent injury or death during operation and installation.

Water Chemistry

Details recommended water quality parameters for optimal UV system performance.

Operation

Basic Systems Controller Operation

Details operation for basic VIQUA controllers, including lamp life and fault indicators.

Plus Systems Controller Operation

Explains operation for Plus series VIQUA controllers, covering UV intensity and advanced features.

Troubleshooting

Common Issues and Solutions

Addresses common system problems, their causes, and recommended solutions for effective operation.

Manufacturers Dose Flow Chart

Dose Flow Rate Guidance

Provides graphical data correlating flow rate with UV dose (fluence) for different models.

Specifications

Home and Professional - Standard Models

Lists technical specifications for standard Home and Professional VIQUA UV systems.

Home and Professional - Plus Models

Details technical specifications for the VIQUA Plus series of Home and Professional UV systems.

Manufacturers Warranty

Warranty Coverage Details

Outlines specific warranty periods for UV chambers, electrical components, lamps, sleeves, and sensors.

Viqua VH200 Specifications

General IconGeneral
Lamp Life9000 hours
Inlet/Outlet Size3/4" MNPT
Chamber Material304 Stainless Steel
Maximum Operating Pressure125 psi (8.6 bar)
Voltage120 V
TypeUV Disinfection System
Maximum Water Hardness120 ppm
Power SupplyStandard Ballast
CertificationsNSF/ANSI 55 Class B

Related product manuals