EasyManuals Logo

Vislink ADVENT DCU5000 User Manual

Default Icon
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Advent Communications
209297 – DCU5000 Drive Control Unit Page 15 of 42
4.8. F7: FREEWHEEL DETECTED
A drive axis freewheel has been detected. It is possible that a freewheel on a drive
display can clear itself and this alarm shows the cause of the axis becoming
uncalibrated.
Possible causes:
Axis hitting physical end stop.
Moving antenna under high wind or snow loading.
This alarm is latched, and has to be cleared through the alarm clear menu option.
4.9. F8: END OF TRAVEL DETECTED
A drive axis travel limit has been detected. The axis causing this will become
uncalibrated.
Possible causes:
Severe axis stall or freewheel causing the calculated angle which the soft stop
uses to be seriously in error.
4.10. F9: TX POL SWITCH FAILED
The TX polarisation switch, if fitted, has been detected in an illegal state or will not
respond to switch commands. Possible causes:
Manual operation of the switch with the DCU on will trigger this alarm.
Switch is disconnected.
Switch is stuck or jammed.
4.11. F10: AZIMUTH STOW SENSOR FAILED
The sensor used to detect the azimuth tab markers has failed. Possible causes:
Sensor disconnected.
Sensor failure.
Metal stuck in sensor.
4.12. F11: ELEVATION STOW SENSOR FAILED
The sensor used to detect the elevation tab markers has failed. Possible causes:
Sensor disconnected.
Sensor failure.
Metal stuck in sensor.
4.13. F12: POL STOW SENSOR FAILED
The sensor used to detect the polarisation markers has failed. Possible causes:
Sensor disconnected.
Sensor failure.
Metal stuck in sensor.
4.14. F13: EL DP SENSOR FAILED
Currently not used in the DCU5000 system. If seen please report the occurrence to
Advent Communications customer support.
4.15. F14: FA DP SENSOR FAILED
Currently not used in the DCU5000 system. If seen please report the occurrence to
Advent Communications customer support.
4.16. F15: EL STOWED SENSOR FAILED
Currently not used in the DCU5000 system. If seen please report the occurrence to
Advent Communications customer support.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vislink ADVENT DCU5000 and is the answer not in the manual?

Vislink ADVENT DCU5000 Specifications

General IconGeneral
BrandVislink
ModelADVENT DCU5000
CategoryControl Unit
LanguageEnglish