Advent Communications
209297 – DCU5000 Drive Control Unit Page 19 of 42
4.53. F53: WOODED AREA DATA ERROR
An error has been detected whilst reading the units wooded area settings. The values
have been set to their default values. If the system requires restricted wooded area
antenna movement, check values and confirm the safe operation of the antenna
system.
4.54. F54: CAL. AREA DATA ERROR
An error has been detected whilst reading the units calibration settings. The values
have been set to their default values.
4.55. F55: FPGA COMPATIBILITY WARNING
The FPGA version is not compatible with the unit software installed. If seen please
report the occurrence to Advent Communications customer support.
4.56. F56: EXT FLASH ERROR
An error has been detected erasing or writing to the DCU5000 flash memory chip.
4.57. F58: HEATSINK FAN STALL DETECTED
The heatsink fan on the motor drive output stage has been detected to be not turning.
This could result in the output stage overheating and shutting down to prevent thermal
damage.
4.58. F59: HMR3300 TEMPERATURE WARNING
The HMR3300 compass unit, if fitted, has detected a device temperature below -10°C
during this session of operation.
4.59. F60: HMR3300 TEMPERATURE ALARM
The HMR3300 compass unit, if fitted, has detected a device temperature below -20°C
during this session of operation.
4.60. F61-F64 ALARM ERROR
These alarms should never be triggered, if seen please report the occurrence to
Advent Communications customer support.