Advent Communications
209297 – DCU5000 Drive Control Unit Page 23 of 42
5.5. REMOTE COMMANDS
5.5.1. STANDARD ADVENT REMOTE COMMANDS
Query Model ID
Command:
QM
Response:
RMODL<Model Text>
<Model Text> DCU5XXX
50YY: NewSwift
52YY: Mantis
53YY: FlyDrive.
54YY: Summit.
YY: Antenna dia. in units of 10cm.
Query Serial Number
Command:
QSN
Response:
Serial No. xxxxxxx
xxxxxxx Seven digit unit serial number
Query Software revision
Command:
QSR
Response:
Software Rev. a.aab.bbc.cc
unit revision a.aa
antOS revision b.bb
antenna control revision c.cc
Query Software Part Number
Command:
QSPN
Response:
SPN<Software Part No String>
<Software Part No String> : ASCII software part number string, max 30 characters.
Query FPGA revision
Command:
QFR
Response:
FRxx.yy
FPGA revision : xx.yy
xx,yy Number 00-99
Query local/remote lock
Command:
QSL
Response:
SLR
x ‘R’ : Remote only option
Set local/remote lock
Command:
SLx
Response:
SLx
x ‘L’: Local
‘R’ : Remote (Only option as the unit has no front panel)