Figure 3.3b – Phone Wiring in North America
Phone wiring in the UK: Line terminals must be connected to pins 2 and 5 of the wall jack.
For all installations: If DSL service is present on the phone line, you must route the phone line through a DSL filter
See 2. CHOOSING THE INSTALLATION LOCATION, note about DSL filters
for details.
3.4 Connecting Wired Zone and Siren
If an expander module is not installed, one wired zone and one low voltage siren can be connected directly to the front
panel PCB. Review Figure 3.1.1.or 3.1.2 and identify symbol “B”.
WIRED ZONE
3
&SIREN WIRING
A. GND
B. Wired Zone
C. Siren
D. For future
use
E. Site external
siren MG
electronics
MG441PDS
or equivalent
6-12VDC,
150 mA Max
F. Magnetic
contact or
any other
contact but
not a
detector
G. Alarm N.C.
Figure 3.4 – Wired Zone and Siren Wiring
3
Wired zones can be enrolled in any zone in the PowerMaster-33 G2 control panel from 01 to 64
D-306917 PowerMaster-33 G2 Installer's Guide 11