3.9 Connecting Power to the Control Panel
Note: This equipment should be installed in accordance with Chapter 2 of the National Fire Alarm Code, ANSI/NFPA 72.
Connect the power cable and close the control panel as shown in Figures 3.9a –3.10.
POWER CABLE CLAMP EXTRACTION AND POWER CONNECTION FOR INTERNAL POWER SUPPLY
Perform steps 1 & 2 on a workbench before mounting.
1. Thick cable entry: Pull out the required wiring
plastic cap (1 of 4).
2. Extract cable clamp (I) for use in the next step.
3. Insert the power cable through the required wiring
channel (A). Route it to the power supply unit (E) and
remove the safety cover (D).
Connect the 2 wires of the power cable to the power
supply terminal block (F) with a screwdriver.
Fasten the screws tightly. Fasten the power cable by
its clamp (B or C) and close the safety cover (D).
4. Connect the power supply output cable (G) to the
power connector (H) in the front panel.
A. Optional wiring channels
B. For thin cable
C. For thick cable (reversed clamp)
D. Safety cover
E. Power supply unit
F. Power supply terminal block
G. Power supply output cable
H. Power connector
(*) Do not route wiring in this area, to enable proper
closure of the control panel.
I. Cable clamp.
Figure 3.9a – Power Cable Clamp Extraction and Power Connection for Internal Power Supply
18 D-306917 PowerMaster-33 G2 Installer's Guide