Switching from ‘AWAY’ to ‘HOME’
Do not disarm the system - simply press
.
Since this operation reduces the security level, the
PowerMax Pro will ask you to key in your master
user code or user code, or present a valid proximity
tag, thus making sure that you are an authorized
user.
PRESS
RESULTANT DISPLAY
ENTER CODE
_ _ _ _
[Enter code] ARMING HOME
Move to interior zone
(Exit delay)
ARM HOME HH:MM
ARM indicator flashes during the armed state.
If an alarm occurred while the system was armed in
the AWAY mode, the display will respond differently:
PRESS
RESULTANT DISPLAY
ENTER CODE
_ _ _ _
[Enter code] ARMING HOME
(Exit delay)
Move to interior zone
HOME HH:MM
(alternating)
ARM HOME MEMORY
ARM indicator flashes during the armed state.
Arming AWAY ‘Instant’
You may arm AWAY or HOME without an entry
delay - any detection in any zone will trigger an
immediate alarm.
If you wish to arm AWAY-INSTANT, proceed as
follows.
PRESS
RESULTANT DISPLAY
ENTER CODE
_ _ _ _
ARMING AWAY
ARMING INSTANT
(alternating)
PLEASE EXIT NOW
(Exit delay)
Vacate the premises AWAY
ARM indicator lights during the armed state.
Arming HOME ‘Instant’
If you wish to arm HOME-INSTANT, proceed as follows:
PRESS
RESULTANT DISPLAY
ENTER CODE
_ _ _ _
ARMING HOME
ARMING HOME
(alternating)
ARM HOME INSTANT
(Exit delay)
Move to interior zone
HOME HH:MM
ARM indicator flashes during the armed state.
Forced Arming AWAY
Forced arming allows you to arm any system
partition even though one zone or several zones are
disturbed, and the NOT READY message is
displayed.
Automatic forced arming only works if the installer
allowed this option while programming your system.
Disturbed zones will be bypassed - they will not be
armed. The protected site will not have maximum
protection.
Note: When forced arming is carried out, the buzzer
“protests” by emitting a continuous tone during the
exit delay until the last 10 seconds of the delay. You
can silence this signal by pressing the arming button
again.
When NOT READY is displayed, Forced arming
“AWAY” is performed as follows:
PRESS
RESULTANT DISPLAY
ENTER CODE
_ _ _ _
ARMING AWAY
PLEASE EXIT NOW
(Exit delay)
(to mute the buzzer)
AWAY
ARM indicator lights during the armed state.
Forced Arming HOME
When NOT READY is displayed, Forced arming
“HOME”, is performed as follows:

Table of Contents