SPECIAL FUNCTIONS
24 D-302542
Command Individual Partition SMS
Format
All Partitions SMS format /
Partition Disable
1 Arm AWAY
"P# AWAY <code>"
"P# AW <code>"
"AWAY <code>"
"AW <code>"
2 Arm AWAY instant
Not supported command "AWAY INST <code>"
"AWI <code>"
3 Arm AWAY Latchkey
Not supported command "LATCHKEY <code>"
"LK <code>"
4 Arm AWAY Latchkey instant
Not supported command "LATCHKEY INST <code>"
"LKI <code>"
5 Arm HOME
"P# HOME <code>"
"P# HM <code>"
"HOME <code>"
"HM <code>"
6 Arm HOME instant
Not supported command "HOME INST <code>"
"HMI <code>"
7 Disarm
"P# DISARM <code>"
"P# DA <code>"
"DISARM <code>"
"DA <code>"
8 Turn light xx on
(xx = 01 – 15)
"LIGHT xx ON <code>"
"LT xx ON <code>"
"LIGHT xx ON <code>"
"LT xx ON <code>"
9 Turn light xx off
(xx = 01 – 15)
"LIGHT xx ON <code>"
"LT xx ON <code>"
"LIGHT xx ON <code>"
"LT xx ON <code>"
10 Turn PGM on
"PGM ON <code>" "PGM ON <code>"
11 Turn PGM off
"PGM OFF <code>" "PGM OFF <code>"
12 Define custom house identity
(see note)
"HOUSE NAME <code><house
ID>"
"HN <code><house ID>"
"HOUSE NAME <code><house
ID>"
"HN <code><house ID>"
13 Query system status
Not supported command
"STATUS <code>"
"ST <code>"
Note: House ID includes up to 16 characters, for example JOHN'S HOUSE.
Reporting by SMS
The PowerMax Pro system can send SMS messages
to a maximum of 4 pre-selected telephone numbers.
Example of the reported SMS messages:
• JOHN’S HOME
**AWAY**
• JOHN’S HOME
**DISARM**
• JOHN’S HOUSE
POWERMAX: LOW BATTERY
GARAGE: LOW BATTERY
• JOHN’S HOUSE
STATUS MESSAGE 01
(Event list is displayed)
Note: Status messages can be sent only to a calling
telephone whose identity number is not blocked by
the user!
Note: The PowerMax Pro may react with a delay to
received SMS messages if a GPRS session is in
progress at the same time.
Conducting a Walk-Test
The walk-test is an indispensable operation by which
you verify that all detectors function properly, without
disturbing the neighbors with loud sirens. The test
must be performed at least once a week, and
should include all detectors in all zones.
Before performing walk-test, all the detectors must
be in normal state. Normal state is achieved when no
motion is made for at least 2 minutes.
Note: During the test period, 24-hour zones will not
cause an alarm if violated, but a fire zone will
function normally.
A typical test will take place as follows:
A. Click
.
The display will read:
WALK TEST
B. Click the button, the display will
prompt you for your user code:
ENTER CODE
_ _ _ _