KNX PARAMETER KNX PARAMETERSETTINGS SETTINGS
Delay on Power-up
Value associated with
backlight ON mode
[0..100%]
Value associated with
backlight OFF mode
[0..100%]
Probe Function
Proximity function
Standby Mode
Acoustic signal on press
5 ÷ 15 seconds 0-100%
0-100%
Through this parameter is possible to set the delay of tran-
smission of telegrams after a power on by selecting the time
by which the device is allowed to send telegrams.
In large systems after a power failure or shutdown this delay
avoids to generate excessive trac on the bus, causing slow
performance or a transmission block.
If there are dierent devices requiring sending telegrams on
the bus after a reset, these delays must be programmed to
prevent trac congestion during the initialization phase.
The input detection and the values of objects are updated at
the end of the transmission delay time
At the end of ETS programming the device behaves like after
a power on.
Temperature Sensor”: measures and sends temperature on
the bus. See par. 6
Thermostat”: controls dierent types of actuators regulating
heating and cooling. See par. 7
“Control Panel”: permit to control a remote KNX thermostat.
See Par. 21
With this parameter, during the ETS conguration, you can
set the brightness of backlight of the button when value is
OFF
With this parameter, during the ETS conguration, you can
set the brightness of backlight of the button when value is
ON
This parameter permit to enable or disable the proximity
funzion of the glass panel
This parameter permit di disable or enable the stanby mode
of the glass panel
This parameter permit di disable or enable the Acoustic
signal on press the glass panel.
When this parameter is enabled an acoustic signal notify that
one button is pressed
Temperature sensor
Thermostat
Control Panel
Disable
Enable
Disable
Enable
Disable
Enable
3. General Parameter Conguration