EasyManuals Logo

Vivax ACP-09CH25AERO User Manual

Vivax ACP-09CH25AERO
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
26
cooling mode, defrosting mode and the current protection.
7.4.2.3 Indoor fan running rules
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and
auto.
The auto fan:
T1-Ts
High
Low
Medium
7.4.2.4 Evaporator low temperature T2 protection.
T2
On
Off
When the evaporator coil temp.T2 keeps lower than setting value, the compressor and outdoor fan will
shut off.
7.4.3 Heating Mode (For Heating & Cooling models)
7.4.3.1 Compressor running rules:
When indoor room temp.T1 is higher than setting value the compressor and outdoor fan will shut off.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vivax ACP-09CH25AERO and is the answer not in the manual?

Vivax ACP-09CH25AERO Specifications

General IconGeneral
BrandVivax
ModelACP-09CH25AERO
CategoryAir Conditioner
LanguageEnglish

Related product manuals