7.2 status
Group: status
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
di_i<0~(ndi-1)> <boolean> 0 1/7 0 => Inactive, normal
1 => Active, triggered
do_i<0~(ndo-1)> <boolean> 0 1/7 0 => Inactive, normal
1 => Active, triggered
daynight day, night 0 7/7 Current status of day, night.
onlinenum_rtsp integer 0 6/7 Current number of RTSP
connections.
onlinenum_httppush integer 0 6/7 Current number of HTTP push
server connections.
eth_i0 <string> <blank> 1/7 Get network information from
mii-tool.
vi_i<0~(nvi-1)> <boolean> 0 1/7 Virtual input
0 => Inactive
1 => Active
7.3 digital input behavior define
Group: di_i<0~(ndi-1)>
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
high 1/1 Indicates open circuit or
closed circuit (inactive
status)
7.4 digital output behavior define
Group: do_i<0~(ndo-1)>
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
Normalstate open,
grounded
open 1/1 Indicate open circuit or
closed circuit (inactive
status)