di <integer> 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
T
he
LSB indicates DI 0.
mdwin <integer> 0 6/6 Indicate the source window id of motion
detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 <integer> 0 6/6 Similar to mdwin. The parameter takes
effect when profile 1 of motion detection
is enabled.
vi <integer> 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input. The
LSB indicates VI 0.
valevel 0,1 0 6/6 Select audio detection event.
0: not select
1: select
valevel0 0,1 0 6/6 Select audio detection profile event.
0: not select
1: select
inter 1~999 1 6/6 Interval of snapshots in minutes.