5. Get Server Parameter Values
Note: The access right depends on the URL directory.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/anonymous/getparam.cgi?[<parameter>]
[&<parameter>…]
http://<servername>/cgi-bin/viewer/getparam.cgi?[<parameter>]
[&<parameter>…]
http://<servername>/cgi-bin/operator/getparam.cgi?[<parameter>]
[&<parameter>…]
http://<servername>/cgi-bin/admin/getparam.cgi?[<parameter>]
[&<parameter>…]
Where the <parameter> should be <group>[_<name>] or <group>[.<name>]. If you do not specify any
parameters, all the parameters on the server will be returned. If you specify only <group>, the parameters
oftherelated group will be returned.
When querying parameter values, the current parameter values are returned.
A successful control request returns parameter pairs as follows:
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: <length>\r\n
\r\n
<parameter pair>
where<parameter pair> is
<parameter>=<value>\r\n
[<parameter pair>]
<length> is the actual length of content.
Example: Request IP address and its response
Request:

Table of Contents

Other manuals for Vivotek FD816C-HF2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vivotek FD816C-HF2 and is the answer not in the manual?

Vivotek FD816C-HF2 Specifications

General IconGeneral
BrandVivotek
ModelFD816C-HF2
CategorySecurity Camera
LanguageEnglish

Related product manuals