User's Manual - 133
1: auto
2: always on
3: keep current value
wdrc_strength 0~2 1 4/4 WDR enhanced.
0: low
1: medium
2: high
agc 0,1,2 1 4/4 Set auto gain control to normal
level or MAX level.
0->2x,
1->4x,
2->8x
(not used in MD8562)
agcmode auto,fixed auto 4/4 Set auto gain control mode.
maxgain 0~100 100 4/4 Manual set maximum gain value.
mingain 0~100 0 4/4 Manual set minimum gain value.
autoiris <boolean> 0 4/4 Enable auto Iris.
(not used in MD8562)
7.10 IR cut control
Group: ircutcontrol (not used in MD8562)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
mode auto,
day,
night,
di,
schedule
<product
dependent>
auto 6/6 Set IR cut control mode
daymodebegintime 00:00~23:59 07:00 6/6 Day mode begin time
daymodeendtime 00:00~23:59 18:00 6/6 Day mod end time
bwmode <boolean> 1 6/6 Switch to B/W in night mode if
enabled
sensitivity low,
normal,
high
normal 6/6 Sensitivity of light sensor