7.15 Time Shift settings
Group: timeshift, c for n channel products, m is stream number (capability.timeshift > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enable <boolean> 0 4/4 Enable time shift streaming.
c<0~(n-1)>_s<0~
(m-1)>_allow
<boolean> 0 4/4 Enable time shift streaming for
specific stream.
7.16 Motion detection settings
Group: motion_c<0~(n-1)> for n channel product
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enable <boolean> 0 4/4 Enable motion detection.
win_i<0~2>_enable <boolean> 0 4/4 Enable motion window 1~3.
win_i<0~2>_name string[14] <blank> 4/4 Name of motion window 1~3.
win_i<0~2>_left 0 ~ 320 0 4/4 Left coordinate of window
position.
win_i<0~2>_top 0 ~ 240 0 4/4 Top coordinate of window
position.
win_i<0~2>_width 0 ~ 320 0 4/4 Width of motion detection
window.
win_i<0~2>_height 0 ~ 240 0 4/4 Height of motion detection
window.
win_i<0~2>_objsize 0 ~ 100 0 4/4 Percent of motion detection
window.
win_i<0~2>_sensitivity 0 ~ 100 0 4/4 Sensitivity of motion detection
window.
7.17 Tempering detection settings
Group: tampering_c<0~(n-1)> for n channel product (capability.tampering > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enable <boolean> 0 4/4 Enable or disable tamper detection.
threshold 0 ~ 255 32 4/4 Threshold of tamper detection.
duration 10 ~ 600 10 4/4 If tampering value exceeds the ‘threshold’ for