CHANGING A CO
2
CYLINDER
WARNING
Wear protective gloves and
safety glasses when changing CO
2
Cylinders.
Close the Valve on top of the empty Cylinder.
Close Empty Cylinder Valve
Using the proper wrench, loosen the Nut on the
Cylinder to disconnect the High-Pressure Hose or
Primary Regulator. Allow residual gas to escape
from the hose.
WARNING
The line is pressurized.
Pressure will be released while performing this
procedure. Handle carefully.
Disconnect High-Pressure Hose
Place the Regulator within safe reach.
Release the Bracket, Strap or Chain securing the
Cylinder.
SECURE CYLINDER
Move empty Cylinder to storage area and secure
safely.
Remove the plastic plug or tape from the new full
Cylinder outlet and discard it.
IMPORTANT ________________________
To avoid confusion, do not replace plastic
plugs in the outlet of empty CO
2
Cylinders.
WARNING
Wear protective gloves and safety
glasses when purging Cylinder. Be sure to point
the Cylinder outlet away from your body.
Purge the replacement Cylinder by quickly opening
and closing the Valve on top to clear any dust or
moisture from the outlet.
Connect the High-Pressure Hose or Primary
Regulator. Make sure the Sealing Washer is seated
correctly.
Tighten the Nut rmly using a wrench.
Open the Valve on top of the Cylinder.
Check for leaks using a solution of soapy water or
a commercial equivalent.
Checking for Leaks
FOR UNITS WITH
OPTIONAL HOT WATER BOILER
Operating Boiler for the First Time:
Make sure installation is correct.
Turn ON the Water Supply Valve.
Plug the Boiler in to an appropriate electrical
supply and press the Power Button on the front of
the unit.
Boiler Start-up
The Power Button will glow green and the unit
will ll to a safe level, above the elements, before
heating.
IMPORTANT ________________________
Boiler has a Water Level Probe Circuit that
must be satisfied before Heating Elements are
energized.
The Ready Light will ash 2 times repeatedly as
the Tank lls.
When the correct water level is reached, the
Controller will energize the Heating Circuit.
Once the water is heated to the preset temperature
(203°F), the Boiler will ll until the temperature
drops by 1 or 2 degrees. The Boiler will then heat
again. This heat/ll cycle continues until the Boiler
is full.
When the Tank is full but still heating, the Ready
Button will remain off. The Ready Button will glow
green when the unit is both full and up to normal
operating temperature.
The Boiler is now ready for use.
ECO MODE
All Boilers incorporate an ECO Mode function.
To Enable ECO Mode:
Press the ECO Mode Button located below the
Ready indicator so that the leaf symbol illuminates
green.
ECO Mode
This mode saves energy by minimizing the energy
wasted during unit down-time.
IMPORTANT ________________________
ECO Mode is most effective in installations
where the unit has a regular OFF period.
To achieve the most benet from the energy saving
ECO Mode on your ECO Boiler unit, follow these
procedures:
Towards the end of the Boiler’s operating period
for a given day, switch the machine to ECO Mode.
This will maintain water at 203°F and the unit’s
Tank will slowly drop to half full.
At the end of the day, the Boiler should be turned
Off.
During the Off period, as there is less water
in the Tank, there will be less energy lost to the
surrounding environment resulting in an energy
saving.
To Disable ECO Mode:
Press the ECO Mode Button again. The leaf symbol
will no longer be illuminated.