VMAC Vehicle Mounted Air Compressors
Toll Free: 1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
11
Initial Startup
During initial startup, the display may show the following:
SOFT START XXXC
The system has started, but the compressor oil temperature
is still cool. The system is in “Unload” Mode, until the
compressor has come up to temperature.
HYD OIL TOO COLD
The hydraulic oil is below -13 F (-25 C), and the system is
cautioning the operator to preheat the hydraulic oil. The
PREDATAIR will not start.
HYD OIL WARMING, HYD XXXF/XXXC
The hydraulic oil is between -13 F(-25 C) and +5 F(-15 C),
and if installed, the cold climate kit (A700146) has been
turned on to help warm the hydraulic oil. The PREDATAIR
won’t start until the hydraulic oil has warmed to +5 F(-15 C).
Normal Operation
The following data can be reviewed by pressing the ON button
repeatedly:
XXXPSI/XXXKPA
COMP XXXF/XXXC
HYD XXXF/XXXC
HRS:XXXX:XX
The following message will be displayed if the system was running,
and the air pressure stayed above the restart pressure for the
duration of the standby delay time:
STANDBY XXXPSI
The hydraulic solenoid is off, and the system is monitoring
air pressure and compressor and hydraulic oil temperatures.
If the air pressure drops below the restart pressure, or the
compressor oil temperature drops below its minimum, it will
restart and rebuild air.