19
Fan not operating.
Check connections.
Check fan and relay.
Failed temperature probe
or bad wiring connections.
Check the temperature probe and
wiring connections in the hydraulic
manifold.
HYD PROBE OPEN
HYD PROBE SHORT
Failed hydraulic
temperature probe or bad
wiring connection.
Check the temperature probe and
wiring connections in the hydraulic
manifold.
COMP PROBE OPEN
COMP PROBE SHORT
Failed compressor
temperature probe or bad
wiring connection.
Check the temperature probe and
wiring connections.
PRESSURE SENSOR?
Failed pressure sensor or
bad wiring connection.
Check the pressure sensor and
wiring connections.
CONNECTION ERR
Failed control box, display
box, or bad wiring
connection.
Check control and display boxes
for damage, and wiring
connections.
BATTERY LOW
or;
System runs then shuts
down, and display resets,
but doesn’t restart.
Wires connecting to
battery positive and
ground too small.
Check wire size requirements in
the installation manual and install
the correct gauge wires.
Low battery voltage.
Check wiring connections.
Measure voltage at the input to the
PREDATAIR when it is running
with the fan on to ensure full
voltage.
Check charging system.
High oil consumption
Compressor, hose, fitting,
or cooler oil leak.
Check system for leaks.
Compressor shaft seal
leaking.
Pull off hydraulic motor and check
for oil inside coupling.
Excessive oil in air line
Excessive oil level.
Check oil level and adjust as
needed.
Coalescer filter plugged.
Check and replace as needed.
Scavenge line plugged.
Check scavenge line and fittings.
Water in air system
FRL
(Filter/Regulator/Lubricator)
failure.
Check drain on filter.
Air reservoir not drained
regularly
Drain reservoir.
Excessive water in
compressor oil.
Allow system to completely cool,
and drain water from tank until oil
comes out. Top up oil as per
manual.
Air pressure relief valve
opens.
Compressor system
pressure exceeding
200psi.
Check pressure sensor.
Air pressure relief valve
failure.
Check valve.
UNLOAD solenoid failed in
ON state.
Check solenoid and wiring.