VMAC – Vehicle Mounted Air Compressors
Toll Free: 1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
Check connections.
Check fan and relay.
Failed temperature probe
or bad wiring connections.
Check the temperature probe and
wiring connections in the hydraulic
manifold.
HYD PROBE OPEN
HYD PROBE SHORT
Failed hydraulic
temperature probe or bad
wiring connection.
Check the temperature probe and
wiring connections in the hydraulic
manifold.
COMP PROBE OPEN
COMP PROBE SHORT
Failed compressor
temperature probe or bad
wiring connection.
Check the temperature probe and
wiring connections.
Failed pressure sensor or
bad wiring connection.
Check the pressure sensor and
wiring connections.
Failed control box, display
box, or bad wiring
connection.
Check control and display boxes
for damage, and wiring
connections.
BATTERY LOW
or;
System runs then shuts
down, and display resets,
but doesn’t restart.
Wires connecting to
battery positive and
ground too small.
Check wire size requirements in
the installation manual and install
the correct gauge wires.
Check wiring connections.
Measure voltage at the input to the
PREDATAIR when it is running
with the fan on to ensure full
voltage.
Check charging system.
Compressor, hose, fitting,
or cooler oil leak.
Compressor shaft seal
leaking.
Pull off hydraulic motor and check
for oil inside coupling.
Excessive oil in air line
Check oil level and adjust as
needed.
Coalescer filter plugged.
Check and replace as needed.
Check scavenge line and fittings.
FRL
(Filter/Regulator/Lubricator)
failure.
Air reservoir not drained
regularly
Excessive water in
compressor oil.
Allow system to completely cool,
and drain water from tank until oil
comes out. Top up oil as per
manual.
Air pressure relief valve
opens.
Compressor system
pressure exceeding
200psi.
Air pressure relief valve
failure.
UNLOAD solenoid failed in
ON state.
Check solenoid and wiring.