76
Cooling system
TAMD162C TAMD163A,
TAMD163P-A
Freshwater system capacity
including head exchanger, approx.................. 88 liters(19.4 Imp. gals/23.2 US gals) 80 liters(17.6 Imp. gals/21.1 US gals)
Thermostats (2)
starts opening at ............................................. 82°C (180°F) 73–77°C (163–171°F)
fully opening at ............................................... 95°C (203°F) 86–90°C (187–194°F)
Scavenger pump/bilge pump
TAMD162C, TAMD163A, TAMD163P-A
Type ................................................................... Impeller
Clutch ................................................................. Electromagnetic
Capacity (liters/minute) at engine speed: Column pressure 5 m (16.4 ft) Column pressure 10 m (32.8 ft)
900 rpm. ........................................................ 152 liters(33.5 Imp. gals/40.1 USgals) 138 liters(30.3 Imp. gals/36.4 US gals)
1200 rpm. ....................................................... 200 liters(44 Imp. gals/52.9 USgals) 185 liters(40.7 Imp. gals /48.8 USgals)
1500 rpm. ....................................................... 258 liters(56.8 Imp. gals/68.1 US gals) 243 liters(53.4 Imp. gals/64.1 US gals)
1800 rpm. ....................................................... 310 liters(68.2 Imp. gals/81.8 US gals) 295 liters(64.9 Imp. gals/77.9 US gals)
1900 rpm. ....................................................... 335 liters(73.7 Imp. gals/88.4 US gals) 318 liters(70 Imp. gals/84 US gals)
Electrical system
TAMD162C TAMD163A,
TAMD163P-A
System voltage .................................................. 24 V 24V
Battery capacity ................................................. 2 x 12V (in series) max. 220Ah 2 x 12V (in series) max. 220Ah
Generator for alternating current
voltage/max. amperage .................................. 28V/60A 28V/60A
output approx.................................................. 1700 W 1700W
brush length .................................................... min. 8 mm (0.315") min. 8 mm (0.315")
Extra generator equipment (accessory)
voltage/max. amperage .................................. 28V/100A 28V/100A
output approx.................................................. 2800 W 2800 W
brush length .................................................... min. 5 mm (0.2") min. 5 mm (0.2")
Battery electrolyte density at +25
o
C (77
o
F)
fully charged battery ....................................... 1.28 g/cm
3
(0.046 lb/in
3
) 1.28 g/cm
3
(0.046 lb/in
3
)
battery recharged at ....................................... 1.24 g/cm
3
(0.044 lb/in
3
) 1.24 g/cm
3
(0.044 lb/in
3
)
Reverse gear
MPM
Type designation ............................................... IRM350A
Gear ratios ......................................................... 1.58:1; 2.07:1; 2.63:1
Angle (output shaft) ............................................
Oil capacity, approx. .......................................... 20 liters (4.4 Imp. gals/5.3 US gals)
Oil grade (in accordance with API system) ....... CC, CD, CE
Viscosity ........................................................... SAE30*
alternative for operation in hot countries ........ SAE40*
Operating oil pressure at oil temperature
75 ±5°C (167 ±9°F):
min. ................................................................. 1.9 MPa (19.3 kp/cm
2
= 275 psi)
max. ................................................................ 2.4 MPa (24.4 kp/cm
2
= 348 psi)
Max. oil temperature .......................................... 85°C (185°F)
Weight, approx. .................................................. 234 kg (515 lbs)
*Note! Only single grade lubricating oil (only one
viscosity number) may be used in the reverse gear.