Ceramic Master E20 en v1 12
6. ERRORS AND CORRECTIVE ACTIONS
General errors
Errors, connected with heating
Errors, connected with the movement of the table
Errors, connected to the vacuum
1 - Mains frequency is not 50 Hz or 60 Hz.
15 - During running of a program: when the
temperature is increasing the needed rate of
increasing cannot be achieved.
19 - The required temperature is not reached for the
selected time.
20 - The required temperature can not be reached
during cooling.
21 - The selected temperature can not be reached
during heating.
22 - Temperature is higher than 1200°С.
23 - Temperature is lower than 5°С.
53 - the drying sensor is not reached for a certain
time when the furnace opens.
78 - the lower sensor is not reached for a certain
time when the furnace opens.
83 - the top sensor is not reached for a certain time
when the furnace closes and a program with
vacuum executes.
90 - it is not possible to reach the sensor for top
position.
91 - it is not possible to reach the sensor for lower
position.
92 - the working table cannot open.
93 - the drying sensor is not reached for a certain
time when the furnace closes.
28 - The selected vacuum is not reached for the
required time.
50 - There exists residual vacuum during the initial
power on procedure.
51 - After releasing the vacuum, for the required
time the vacuum is not released entirely.
75 - The vacuum can not be released in programming
mode.